2320173 Phoenix Contact Redundancy Modules

2320173 on Power Resource International
Phoenix Contact

Part#:2320173

Manufacturer:Phoenix Contact

Category:Redundancy Modules

Product Lifecycle:Active

Get a quick Quote!

Active QUINT redundancy module for DIN rail mounting with Auto Current Balancing ACB technology and monitoring functions, input: 24 V DC, output: 24 V DC/2 x 10 A or 1 x 20 A, including mounted UTA 107/30 universal DIN rail adapter

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Redundancy Modules that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2320173 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Width
    32 mm
  • Installation distance right/left
    5 mm / 5 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Installation height
    2000 m
  • Nominal output voltage
    0.1 V (< DC input)
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Connection method
    Screw connection
  • Width with alternative assembly
    122 mm
  • Degree of protection
    IP20
  • Nominal input current
    2x 10 A (-25 °C ... 60 °C)
  • Connection in series
    No
  • Power loss nominal load max.
    2 W (IOUT = 20 A)
  • MTBF (IEC 61709, SN 29500)
    > 1000000 h (40 °C)
  • Conductor cross section solid max.
    4 mm²
  • Contact discharge
    8 kV (Test Level 4)
  • Height with alternative assembly
    130 mm
  • Depth with alternative assembly
    35 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Max. permissible relative humidity (operation)
    ≤ 100 % (at 25 °C, non-condensing)
  • Derating
    60 °C ... 70 °C (2.5%/K)
  • Net weight
    0.4 kg
  • Depth
    125 mm
  • Ambient temperature (start-up type tested)
    -40 °C
  • Nominal input voltage range
    24 V DC
  • Maximum input current
    2x 15 A (-25°C ... 40°C)
  • Housing material
    Steel sheet, zinc-plated
  • Conductor cross section flexible max.
    2.5 mm²
  • Degree of pollution
    2
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Stripping length
    10 mm
  • EMC requirements for noise emission
    EN 61000-6-3
  • Discharge in air
    15 kV (Test Level 4)
  • UNSPSC 12.01
    39121004
  • UNSPSC 21.0
    32151504
  • Nominal output current (IN)
    20 A (Increasing power)
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Electrostatic discharge
    EN 61000-4-2
  • UNSPSC 6.01
    30211502
  • UNSPSC 18.0
    32151504
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section AWG min.
    16
  • Screw thread
    M3
  • Electromagnetic HF field
    EN 61000-4-3
  • UNSPSC 13.2
    32151504
  • Height
    130 mm
  • Installation distance top/bottom
    50 mm / 50 mm
  • Input voltage range
    18 V DC ... 28 V DC (SELV)
  • Efficiency
    > 98 %
  • UNSPSC 7.0901
    39121004
  • UNSPSC 19.0
    32151504
  • Protection class
    III
  • ECLASS 7.0
    27371010
  • ETIM 4.0
    EC000599
  • UNSPSC 11
    39121004
  • UNSPSC 20.0
    32151504
  • Standard - Electrical safety
    EN 60950-1/VDE 0805 (SELV)
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Input
    1 kV (Test Level 2 - symmetrical)
  • Output
    1 kV (Test Level 2 - symmetrical)
  • Criterion A
    Normal operating behavior within the specified limits.
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 5.1
    27371000
  • ETIM 3.0
    EC000599
  • Conductor cross section AWG max.
    12
  • UL approvals
    UL/C-UL listed UL 508
  • Test field strength
    10 V/m (Test Level 3)
  • Surge voltage load (surge)
    EN 61000-4-5
  • Voltage
    10 V (Test Level 3)
  • ECLASS 11.0
    27371010
  • ECLASS 5.0
    27371000
  • Conductor cross section flexible min.
    0.2 mm²
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Conducted interference
    EN 61000-4-6
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27250300
  • ECLASS 6.0
    27371000
  • Frequency range
    0.15 MHz ... 80 MHz
  • Comments
    Criterion A
  • Assembly instructions
    alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Fast transients (burst)
    EN 61000-4-4
  • I/O/S
    asymmetrical
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 10.0.1
    27371010
  • ECLASS 4.1
    27250300
  • ECLASS 9.0
    27371010
  • ETIM 7.0
    EC000683
  • ETIM 6.0
    EC000683

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?