2320144 Phoenix Contact DC/DC Converters
Part#:2320144
Manufacturer:Phoenix Contact
Category:DC/DC Converters
Product Lifecycle:Active
Get a quick Quote!
Primary-switched QUINT DC/DC converter for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 48 V DC, output: 24 V DC/5 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2320144 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth 125 mm
- Installation distance top/bottom 50 mm / 50 mm (≤ 70 °C)
- Nominal input voltage range 48 V DC
- Mains buffering time > 14 ms (48 V DC)
- POWER BOOST (IBoost) 6.25 A (-25 °C ... 40 °C permanent, UOUT = 24 V DC )
- Feedback voltage resistance 35 V DC
- Net weight 0.7 kg
- Insulation voltage input/output 1.5 kV (type test)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Stripping length 7 mm
- EMC requirements for noise emission EN 61000-6-3
- Standard – Safety extra-low voltage EN 60950-1 (SELV)
- Electrostatic discharge EN 61000-4-2
- Contact discharge 8 kV (Test Level 4)
- Input 1 kV (Test Level 2 - symmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 5.0 27210900
- ECLASS 9.0 27210901
- UNSPSC 11 39121004
- UNSPSC 20.0 39121041
- Height 130 mm
- Installation distance right/left 0 mm / 0 mm (≤ 70 °C)
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Current consumption 3.5 A (48 V DC)
- Input fuse 10 A (slow-blow, internal)
- Setting range of the output voltage (USet) 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
- Connection in series yes
- Max. capacitive load unlimited
- Peak switching voltages nominal load < 5 mVPP (20 MHz)
- Efficiency > 91.5 %
- Conductor cross section flexible max. 2.5 mm²
- EMC requirements for noise immunity EN 61000-6-1
- Rail applications EN 50121-4
- Fast transients (burst) EN 61000-4-4
- Conducted interference EN 61000-4-6
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 4.0 27210900
- ECLASS 4.1 27210900
- ETIM 6.0 EC002046
- UNSPSC 7.0901 39121004
- UNSPSC 19.0 39121041
- Width 32 mm
- Width with alternative assembly 122 mm
- Installation distance right/left (active) 15 mm / 15 mm (≤ 70 °C)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of pollution 2
- Input voltage range 30 V DC ... 60 V DC
- Nominal output voltage 24 V DC ±1 %
- Nominal output current (IN) 5 A (-25 °C ... 60 °C)
- Derating 60 °C ... 70 °C (2.5%/K)
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Maximum power dissipation in no-load condition 2.7 W
- Connection method Pluggable screw connection
- Conductor cross section flexible min. 0.2 mm²
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Electromagnetic HF field EN 61000-4-3
- Frequency range 0.15 MHz ... 80 MHz
- Output 1 kV (Test Level 2 - symmetrical)
- Voltage 10 V (Test Level 3)
- ECLASS 10.0.1 27210901
- ECLASS 5.1 27210900
- ETIM 4.0 EC002540
- UNSPSC 13.2 39121041
- UNSPSC 21.0 39121041
- Height with alternative assembly 130 mm
- Degree of protection IP20
- Ambient temperature (start-up type tested) -40 °C
- Climatic class 3K3 (in acc. with EN 60721)
- Type of protection Transient surge protection
- Selective Fuse Breaking (ISFB) 30 A (12 ms)
- Protection against overvoltage at the output (OVP) < 35 V DC
- Residual ripple < 25 mVPP
- Protection class III
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG min. 24
- Screw thread M3
- Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
- UL approvals UL/C-UL listed UL 508
- Discharge in air 15 kV (Test Level 4)
- Test field strength 10 V/m (Test Level 3)
- Signal 1 kV (Test Level 2 - asymmetrical)
- I/O/S asymmetrical
- ECLASS 11.0 27210901
- ECLASS 6.0 27210900
- ETIM 7.0 EC002046
- UNSPSC 12.01 39121004
- Depth with alternative assembly 35 mm
- Installation distance top/bottom (active) 50 mm / 50 mm (≤ 70 °C)
- Inrush current < 5 A (typical)
- Recommended breaker for input protection 10 A ... 16 A (Characteristics B, C, D, K)
- Protective circuit/component Varistor
- Connection in parallel Yes, for redundancy and increased capacity
- Active current limitation Approximately 6.9 A
- Power loss nominal load max. 11 W
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section AWG max. 12
- Standard - Safe isolation DIN VDE 0100-410
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Comments Criterion A
- Surge voltage load (surge) EN 61000-4-5
- Criterion A Normal operating behavior within the specified limits.
- REACh SVHC Lead 7439-92-1
- ECLASS 7.0 27210901
- UNSPSC 6.01 30211502
- UNSPSC 18.0 39121041
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?