Primary-switched QUINT DC/DC converter for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 24 V DC, output: 24 V DC/20 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2320102 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width with alternative assembly 122 mm
- Installation distance top/bottom (active) 50 mm / 50 mm (≤ 70 °C)
- Installation distance top/bottom 50 mm / 50 mm (≤ 70 °C)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Input voltage range 18 VÂ DC ... 32 VÂ DC
- Extended input voltage range in operation 14 VÂ DC ... 18 VÂ DC (Derating)
- Type of protection Transient surge protection
- POWER BOOST (IBoost) 25 A (-25 °C ... 40 °C permanent, UOUT = 24 V DC )
- Protection against overvoltage at the output (OVP) < 35 VÂ DC
- Residual ripple < 20 mVPP
- Power loss nominal load max. 39 W
- Insulation voltage input/output 1.5 kV (type test)
- Conductor cross section AWG min. 24
- Conductor cross section AWG max. 12
- Screw thread M3
- Standard - Electrical safety ENÂ 60950-1/VDEÂ 0805 (SELV)
- UL approvals UL/C-UL listed UL 508
- Discharge in air 15 kV (Test Level 4)
- Electromagnetic HF field ENÂ 61000-4-3
- Signal 1 kV (Test Level 2 - asymmetrical)
- Voltage 10 V (Test Level 3)
- Height 130 mm
- Installation distance right/left 0 mm / 0 mm (≤ 70 °C)
- Depth 125 mm
- Installation distance right/left (active) 15 mm / 15 mm (≤ 70 °C)
- Ambient temperature (start-up type tested) -40 °C
- Degree of pollution 2
- Current consumption 28 A (24 V, IBOOST)
- Mains buffering time typ. 10 ms (24Â VÂ DC)
- Nominal output voltage 24 V DC ±1 %
- Setting range of the output voltage (USet) 18 VÂ DC ... 29.5 VÂ DC (> 24 VÂ DC, constant capacity restricted)
- Connection in parallel Yes, for redundancy and increased capacity
- Peak switching voltages nominal load < 10 mVPP (20Â MHz)
- ECLASS 11.0 27210901
- Width 82 mm
- Depth with alternative assembly 85 mm
- Degree of protection IP20
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Recommended breaker for input protection 40 A ... 50 A (Characteristics B, C, D, K)
- Nominal output current (IN) 20 A (-25 °C ... 60 °C)
- Derating 60 °C ... 70 °C (2.5%/K)
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Max. capacitive load unlimited
- Maximum power dissipation in no-load condition 2.2 W
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section solid min. 0.2 mm²
- EMC requirements for noise emission ENÂ 61000-6-3
- Rail applications ENÂ 50121-4
- Frequency range 0.15 MHz ... 80 MHz
- Fast transients (burst) ENÂ 61000-4-4
- Comments Criterion A
- Output 1 kV (Test Level 2 - symmetrical)
- REACh SVHC Lead 7439-92-1
- ECLASS 5.1 27210900
- ETIM 4.0 EC002542
- UNSPSC 18.0 39121041
- UNSPSC 19.0 39121041
- UNSPSC 20.0 39121041
- Height with alternative assembly 130 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C derating, 2.5 %/K, startup at -40°C type-tested)
- Climatic class 3K3 (in acc. with EN 60721)
- Nominal input voltage range 24 VÂ DC
- Inrush current < 26 A (typical)
- Protective circuit/component Varistor
- Selective Fuse Breaking (ISFB) 120 A (12 ms)
- Connection in series yes
- Active current limitation approx. 29 A
- Efficiency > 93 %
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section flexible min. 0.2 mm²
- Stripping length 8 mm
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Shipbuilding approval DNVÂ GLÂ (EMCÂ B)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Test field strength 10 V/m
- Surge voltage load (surge) ENÂ 61000-4-5
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 10.0.1 27210901
- ECLASS 6.0 27210900
- ECLASS 4.1 27210900
- ETIM 7.0 EC002046
- UNSPSC 11 39121004
- UNSPSC 12.01 39121004
- Net weight 1.7 kg
- Protection class III
- Connection method Screw connection
- Conductor cross section flexible max. 2.5 mm²
- EMC requirements for noise immunity ENÂ 61000-6-1
- Standard – Safety extra-low voltage EN 60950-1 (SELV)
- Standard - Safe isolation DINÂ VDEÂ 0100-410
- Electrostatic discharge EN 61000-4-2
- Contact discharge 8 kV (Test Level 4)
- Input 1 kV (Test Level 2 - symmetrical)
- Conducted interference ENÂ 61000-4-6
- I/O/S asymmetrical
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 5.0 27210900
- ETIM 6.0 EC002046
- UNSPSC 7.0901 39121004
- UNSPSC 21.0 39121041
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 4.0 27210900
- ECLASS 9.0 27210901
- ECLASS 7.0 27210901
- UNSPSC 6.01 30211502
- UNSPSC 13.2 39121041
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?