Primary-switched MINI DC/DC converter for DIN rail mounting, input: 12 - 24 V DC, output: 5 - 15 V DC/2 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2320018 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Width
    22.5 mm
  • Installation distance top/bottom
    50 mm / 50 mm (≤ 70 °C)
  • Max. permissible relative humidity (operation)
    ≤ 95 % (At +25°C, non-condensing)
  • Current consumption
    2.3 A (12 V DC)
  • Nominal output current (IN)
    2 A (-25 °C ... 60 °C)
  • Maximum power dissipation in no-load condition
    < 1 W
  • Net weight
    0.2 kg
  • Assembly instructions
    alignable: horizontally 0 mm, vertically 50 mm
  • Conductor cross section solid max.
    2.5 mm²
  • Screw thread
    M3
  • Status display
    "DC OK" LED green
  • Tightening torque, min
    0.5 Nm
  • UL approvals
    UL/C-UL listed UL 508
  • Fast transients (burst)
    EN 61000-4-4
  • Voltage dips
    EN 61000-4-11
  • ECLASS 10.0.1
    27210901
  • ECLASS 11.0
    27210901
  • ETIM 7.0
    EC002046
  • UNSPSC 13.2
    39121041
  • UNSPSC 21.0
    39121041
  • Depth
    107 mm
  • Nominal input voltage range
    12 V DC ... 24 V DC
  • Inrush current
    < 10 A (typical)
  • Connection in parallel
    Yes, for assembling redundant systems and increasing efficiency
  • Typical response time
    < 0.5 s
  • Power loss nominal load max.
    < 4.2 W
  • MTBF (IEC 61709, SN 29500)
    > 2072000 h (40 °C)
  • Conductor cross section flexible min.
    0.2 mm²
  • Output description
    UOUT > 0.9 x UN: High signal
  • Tightening torque max
    0.6 Nm
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Electromagnetic HF field
    EN 61000-4-3
  • ECLASS 4.0
    27210900
  • ECLASS 7.0
    27210901
  • ECLASS 9.0
    27210901
  • UNSPSC 11
    39121004
  • UNSPSC 19.0
    39121041
  • Height
    99 mm
  • Degree of protection
    IP20
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> +60°C derating)
  • Mains buffering time
    typ. 4 ms (12 V DC)
  • Setting range of the output voltage (USet)
    5 V DC ... 15 V DC
  • Protection against overvoltage at the output (OVP)
    < 25 V DC
  • Efficiency
    > 88 % (at 24 V DC and nominal values)
  • Insulation voltage input/output
    1.5 kV (type test)
  • Connection method
    Pluggable screw connection
  • Conductor cross section AWG max.
    14
  • Output name
    DC OK active
  • Note on status display
    UOUT > 0.9 x UN: LED ON
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard - Electrical safety
    EN 60950-1/VDE 0805 (SELV)
  • Electrostatic discharge
    EN 61000-4-2
  • Surge voltage load (surge)
    EN 61000-4-5
  • ECLASS 4.1
    27210900
  • ECLASS 6.0
    27210900
  • ETIM 4.0
    EC002542
  • UNSPSC 7.0901
    39121004
  • UNSPSC 20.0
    39121041
  • Installation distance right/left
    0 mm / 0 mm (≤ 70 °C)
  • Degree of pollution
    2
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Frequency range DC
    0 Hz
  • Nominal output voltage
    12 V DC ±1 %
  • Derating
    60 °C ... 70 °C (2.5%/K)
  • Feedback voltage resistance
    30 V DC
  • Peak switching voltages nominal load
    < 10 mVPP (20 MHz)
  • Protection class
    III
  • Housing material
    Polyamide (PA)
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible max.
    2.5 mm²
  • Stripping length
    7 mm
  • Output voltage
    Uout
  • Standard - Safe isolation
    DIN VDE 0100-410
  • CSA
    CSA-C22.2 No. 107.1-01
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • REACh SVHC
    Lead 7439-92-1
  • ETIM 3.0
    EC001039
  • ETIM 6.0
    EC002046
  • UNSPSC 12.01
    39121004
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Input voltage range
    10 V DC ... 32 V DC (> 10.5 V DC start)
  • Input fuse
    6.3 A (slow-blow, internal)
  • Connection in series
    yes
  • Residual ripple
    < 20 mVPP (20 MHz)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section AWG min.
    24
  • Continuous load current
    ≤ 20 mA
  • EMC requirements for noise emission
    EN 61000-6-3
  • Rail applications
    EN 50121-4
  • Conducted interference
    EN 61000-4-6
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 5.0
    27210900
  • ECLASS 5.1
    27210900
  • UNSPSC 6.01
    30211502
  • UNSPSC 18.0
    39121041

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?