Single-channel, electronic fuse for the protection of 24 V loads. 24VDC, 1 Amp. Simple potential distribution using terminal blocks from the CLIPLINE complete system. With status output, reset input, and electronic interlock. For installation on DIN rail

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Circuit Protection & Load Centers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1135751 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • ECLASS 9.0
    27141116
  • Depth
    55.6 mm (incl. DIN rail 7.5 mm)
  • Flammability rating according to UL 94
    V-0
  • Number of positions
    1
  • Rated current IN
    24 A DC (Total current input)
  • Tripping method
    E (electronic)
  • Dielectric strength
    max. 35 V DC (Load circuit)
  • Short-circuit switching capacity
    300 A
  • Stripping length
    8 mm
  • Conductor cross section, flexible, with ferrule, with plastic sleeve
    0.2 mm² ... 2.5 mm²
  • Pulse length reset input
    ≥ 50 ms (High)
  • Channel LED off
    off (Channel switched off)
  • Connection name
    Main circuit OUT
  • ECLASS 10.0.1
    27140401
  • Height
    105.8 mm
  • Humidity test
    96 h, 95 % RH, 40 °C
  • Altitude
    ≤ 3000 m up to 52 °C (amsl (above mean sea level))
  • Type
    DIN rail module, one-piece
  • Operating voltage
    18 V DC ... 30 V DC
  • Feedback resistance
    max. 35 V DC
  • Waiting time after switch off of a channel
    5 s (at overload / short circuit)
  • Temperature derating
    21 A (Total current at 60°C)
  • Voltage drop
    0.04 V (at 1 A)
  • Output voltage status output
    24 V DC (Error)
  • Conductor cross section AWG
    24 ... 12
  • Current consumption reset input
    typ. 0.4 mA (at 24 V DC)
  • Channel LED yellow
    lit (Channel switched on, channel load > 80% )
  • Connection method
    Push-in connection
  • Vibration
    B
  • Ambient temperature (storage/transport)
    -40 °C ... 70 °C
  • Mounting type
    DIN rail: 35 mm
  • Degree of pollution
    2
  • Measuring tolerance I
    ± 15 %
  • Closed circuit current I0
    typ. 8 mA
  • MTBF (IEC 61709, SN 29500)
    28571428 h (at 25 °C with 21 % load)
  • Max. capacitive load load circuit
    19000 µF (Depending on the current setting and the short-circuit current available)
  • Conductor cross section flexible, with ferrule without plastic sleeve
    0.2 mm² ... 2.5 mm²
  • Channel LED green
    lit (Channel switched on)
  • Designation
    Shipbuilding approval
  • Humidity
    B
  • Ambient temperature (operation)
    -30 °C ... 60 °C
  • Shock (operation)
    30g (IEC 60068-2-27, Test Ea)
  • Color
    traffic grey A RAL 7042
  • Fuse type
    electronic
  • Rated voltage
    24 V DC
  • Efficiency
    > 99 %
  • Module initialization time
    1 s
  • Undervoltage switch-off load circuit
    ≤ 17.8 V DC (active)
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • Input voltage reset input
    7 V DC ... 30 V DC (Reset with falling edge)
  • Channel LED red
    lit (Channel switched off, over- or undervoltage active)
  • Standards/specifications
    EN 61000-6-2 EMC – Immunity for industrial areas
  • Enclosure
    A
  • REACh SVHC
    Lead 7439-92-1
  • Width
    6.2 mm
  • Degree of protection
    IP20
  • Vibration (operation)
    10 Hz ... 59.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc)
  • Protection class
    III
  • Rated surge voltage
    0.5 kV
  • Fail-safe element
    5 A DC
  • Power dissipation
    typ. 0.15 W (No-load operation)
  • Required backup fuse
    Only required if Imax of the power supply > the short-circuit switching capacity. Integrated failsafe element.
  • Shutdown time load circuit
    ≤ 10 ms (for short circuit > 2.0 x IN)
  • Overvoltage switch-off shutdown load circuit
    ≥ 30.5 V DC (active)
  • Output current status output
    max. 0.015 A (Short-circuit-proof)
  • Voltage reset input
    < 5 V DC (Low state)
  • Identification
    DNV GL
  • Temperature
    D
  • EMC
    B
  • ECLASS 11.0
    27140401

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty