1111634 Phoenix Contact AC/DC Power Supplies
Part#:1111634
Manufacturer:Phoenix Contact
Category:AC/DC Power Supplies
Product Lifecycle:Active
Get a quick Quote!
TRIO POWER primary-switched power supply in IP67 die-cast housing, input: 1-phase, output: 24 V DC / 10 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1111634 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 240 mm
- Ambient temperature (operation) -25 °C ... 70 °C (Derating >60°C: 2.5 %/K)
- Max. permissible relative humidity (operation) ≤ 100 % (at 25 °C, non-condensing)
- Permissible humidity (operation) ≤ 100 % (at 25 °C, non-condensing)
- Discharge current to PE < 3.5 mA
- Inrush current ≤ 25 A (typical)
- Mains buffering time > 15 ms (120 V AC)
- Nominal output voltage 24 V DC ±1 %
- Connection in series No
- Residual ripple ≤ 10 mVPP
- Power loss nominal load max. < 22 W (120 V AC)
- Insulation voltage input/output 3 kV AC (type test)
- Type of locking M12 screw locking
- Standard designation Degrees of protection provided by enclosures (IP code)
- Conducted noise emission EN 55016
- Electromagnetic HF field EN 61000-4-3
- Fast transients (burst) EN 61000-4-4
- Voltage dips EN 61000-4-11
- Voltage dip 0 %
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Degree of pollution 3
- Input voltage range 100 V AC ... 240 V AC 10 %
- Nominal power consumption 285 VA
- Type of protection Transient surge protection
- Dynamic Boost (IDyn.Boost) 15 A (5 s)
- Feedback voltage resistance ≤ 35 V DC
- Maximum power dissipation in no-load condition < 10 W (120 V AC)
- Assembly instructions Alignable: 20 mm horizontally, 50 mm vertically above, 100 mm vertically below
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Comments Criterion A
- Output 1 kV (Test Level 3 - symmetrical)
- Frequency 50 Hz
- REACh SVHC Lead 7439-92-1
- Width 136 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Dielectric strength maximum ≤ 300 V AC 15 s
- Current consumption 2.8 A (100 V AC)
- Power factor (cos phi) 0.93
- Connection in parallel no
- Output power 240 W
- MTBF (IEC 61709, SN 29500) > 1800000 h (25 °C)
- Connection method M12 circular connector
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Contact discharge 6 kV (Test Level 3)
- Electrostatic discharge EN 61000-4-2
- Signal 1 kV (Test Level 2 - asymmetrical)
- Conducted interference EN 61000-4-6
- Criterion A Normal operating behavior within the specified limits.
- Degree of protection IP67
- Installation height ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
- Nominal input voltage range 100 V AC ... 240 V AC
- Frequency range (fN) 50 Hz ... 60 Hz ±10 %
- Protective circuit/component Varistor
- Nominal output current (IN) 10 A
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Net weight 1.5 kg
- Range of positions 4 Socket
- Noise emission EN 55016
- Test field strength 10 V/m (Test Level 3)
- Surge voltage load (surge) EN 61000-4-5
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- Depth 53 mm
- Ambient temperature (start-up type tested) -25 °C
- Climatic class 3K3 (in acc. with EN 60721)
- AC frequency range 50 Hz ... 60 Hz ±10 %
- Recommended breaker for input protection 6 A ... 16 A (US/CAN: branch circuit protection < 20 A) (Characteristic B, C, D, K or comparable)
- Input fuse 6.3 A (internal (device protection))
- Derating > 60 °C ... 70 °C (2.5%/K)
- Protection against overvoltage at the output (OVP) ≤ 30 V DC
- Efficiency typ. 91 % (120 V AC)
- Protection class I
- Coding L-coded
- Standards/regulations EN/IEC 60529
- Harmonic currents EN 61000-3-2
- Frequency range 0.15 MHz ... 80 MHz
- Input 2 kV (Test Level 4 - symmetrical)
- Voltage 230 V AC
- Number of periods 1 period
- ECLASS 9.0 27040701
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing