Bolt connection terminal block, for railway applications, nom. voltage: 1800 V, nominal current: 353 A, connection method: Bolt connection, number of connections: 2, number of positions: 1, width: 49 mm, color: gray, mounting type: NS 35/7,5, NS 35/15, Fl
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1110386 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Number of levels 1
- Color gray
- Number of positions 1
- Flammability rating according to UL 94 V0
- Nominal current IN 353 A (with 185 mm² conductor cross section)
- Maximum power dissipation for nominal condition 11.3 W
- Result of surge voltage test Test passed
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Result of voltage-drop test Test passed
- Result of temperature-rise test Test passed
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Acceleration 30g
- Number of shocks per direction 3
- Length 235.1 mm
- Conductor cross section flexible min. 95 mm²
- Cable lug connection according to standard In accordance with customer specifications
- AWG min 4/0
- Hole diameter, min. 13.2 mm
- Permissible humidity (storage/transport) 30 % ... 70 %
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 11.0 27141120
- ETIM 4.0 EC000897
- UNSPSC 11 39121410
- UNSPSC 20.0 39121410
- Nominal cross section 185 mm²
- Degree of pollution 3
- Test duration per axis 5 h
- Relative insulation material temperature index (Elec., UL 746 B) 150 °C
- Width 49 mm
- Height NS 35/15 89.5 mm
- Connection 1 level
- Stripping length The stripping length depends on the specification provided by the cable lug manufacturer.
- Min. AWG conductor cross section, flexible 4/0
- Bolt diameter 12 mm
- Screw thread M12
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 5.0 27141100
- ECLASS 6.0 27141100
- ETIM 6.0 EC000897
- UNSPSC 19.0 39121410
- Note Connection bolts
- Potentials 1
- Insulating material PA
- Insulating material group I
- Nominal voltage UN 1800 V
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Note regarding shock protection With closed cover
- Result of power-frequency withstand voltage test Test passed
- Result of flexion and pull-out test Test passed
- Tensile test result Test passed
- Short circuit stability result Test passed
- Result of thermal test Test passed
- Test spectrum Service life test category 2, bogie-mounted
- ASD level 6.12 (m/s2)2/Hz
- Shock test result Test passed
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Pitch 49 mm
- Connection in acc. with standard DIN EN 50124-1:2017-12
- Max. cross section for cable lug connection 185 mm²
- Bolt length 36 mm
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- ECLASS 5.1 27141100
- ECLASS 7.0 27141120
- ECLASS 9.0 27141120
- UNSPSC 13.2 39121410
- UNSPSC 21.0 39121410
- Number of connections 2
- Overvoltage category III
- Open side panel No
- Back of the hand protection guaranteed
- Surge voltage test setpoint 9.8 kV
- Bending test rotation speed 10 rpm
- Result of tight fit on support Test passed
- Bending test conductor cross section/weight 185 mm² /16.8 kg
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Oscillation, broadband noise test result Test passed
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Height NS 35/7,5 82 mm
- Connection method Bolt connection
- Max. AWG conductor cross section, flexible 400
- AWG max 400
- Cable lug width, max. 39 mm
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 4.0 27141100
- ECLASS 4.1 27141100
- UNSPSC 7.0901 39121410
- UNSPSC 18.0 39121410
- Area of application Railway industry
- Maximum load current 450 A
- Finger protection guaranteed
- Power frequency withstand voltage setpoint 2.2 kV
- Bending test turns 135
- Requirements, voltage drop U1 ≤ 3.2 mV; U2 ≤ 1.5 x U1
- Conductor cross section short circuit testing 185 mm²
- Short-time current 22.2 kA
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Shock form Semi-sinusoidal
- Shock duration 18 ms
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Conductor cross section flexible max. 185 mm²
- Min. cross section for cable lug connection 95 mm²
- Additional text Customer-specific double-hole cable lug, 13.2 mm hole diameter, 30 mm hole spacing
- Tightening torque max 44 Nm
- Tightening torque, min 40 Nm
- ECLASS 10.0.1 27141120
- ETIM 7.0 EC000897
- UNSPSC 6.01 30211811
- UNSPSC 12.01 39121410
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?