1104976 Phoenix Contact Electrical Safety Devices

1104976 on Power Resource International
Phoenix Contact

Part#:1104976

Manufacturer:Phoenix Contact

Category:Electrical Safety Devices

Product Lifecycle:Active

Get a quick Quote!

Safe extension module with 4 safe outputs (2 A), 4 reset inputs, 8 signal outputs, TBUS interface, up to SILCL 3, cat. 4/PL e, SIL 3, plug-in screw terminal block, TBUS connector included

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1104976 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Indication
    2 x LED (red)
  • Stripping length
    7 mm
  • Height
    112.58 mm
  • Ambient temperature (operation)
    -10 °C ... 55 °C (observe derating)
  • Max. permissible humidity (storage/transport)
    95 % (non-condensing)
  • Power consumption at US
    < 12 mW (Outputs inactive)
  • Protective circuit
    Suppressor diode
  • Number of inputs
    4
  • Cable length
    max. 100 m (per output)
  • Nominal output voltage
    24 V DC (Supply via A1)
  • Ohmic load
    min. 10 Ω (Observe limiting continuous current)
  • Switching frequency
    max. 1/4 x tCycle [Hz]
  • Output voltage range
    18.2 V DC ... 27.8 V DC (US - 1 V)
  • Nominal operating mode
    100% operating factor
  • Min. degree of protection of inst. location
    IP54
  • Housing color
    yellow
  • Protection class
    III (EN 50178)
  • Depth
    113.6 mm
  • Rated control supply current IS
    < 0.5 mA (Outputs inactive)
  • Description
    Output supply, O3, O4
  • Protective circuit/component
    Suppressor diode
  • Nominal output voltage range
    18.6 V DC ... 28.2 V DC (US - 0.6 V)
  • Max. inductive load
    max. 2.4 mH
  • Short-circuit protection
    Yes (self-limitation at 1.1 A)
  • Maximum inrush current
    1.1 A (Δt = 3 s  at Us)
  • Restart time
    min. 5 s (Boot time)
  • Assembly instructions
    Observe derating
  • Connection method
    Screw connection
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Performance level (PL)
    e (2-channel wiring)
  • Standards/regulations
    EN 50178
  • Rated surge voltage/insulation
    Basic insulation 4 kV between 24 V power supply and I/Os to the housing
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • Response time
    see user manual
  • Ambient temperature (storage/transport)
    -20 °C ... 85 °C
  • Torque
    0.5 Nm ... 0.6 Nm
  • Designation
    Air clearances and creepage distances between the power circuits
  • Filter time
    250 ms ±2 ms (Test pulse rate > 500 ms)
  • Description of the input
    IEC 61131-2 type 3
  • Output description
    PNP, IEC 61131-2 Typ 0,1
  • Limiting continuous current
    100 mA (per channel)
  • Error detection time at 1-channel structure
    < 3.5 s (OFF state)
  • Voltage
    24 V DC (via 24 V)
  • Cycle time
    see user manual
  • Housing material
    Polyamide PA non-reinforced
  • pluggable
    Yes
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Screw thread
    M3
  • Rated insulation voltage
    250 V AC
  • Vibration (operation)
    10 Hz ... 150 Hz, 2g
  • ECLASS 11.0
    27371819
  • Width
    22.61 mm
  • Max. permissible relative humidity (operation)
    95 % (non-condensing)
  • Current consumption
    typ. 10 mA (typically with US)
  • Input name
    Reset inputs
  • Input voltage range "1" signal
    11 V DC ... 28.8 V DC
  • Input current range "0" signal
    < 1 mA
  • Output name
    O1, O2, O3, O4
  • Leakage current
    max. 100 µA
  • Test pulses
    < 120 µs (Test pulse width of low test pulses)
  • Mounting position
    vertical or horizontal
  • Mounting type
    DIN rail mounting
  • Status display
    12 x LED (yellow)
  • Safety Integrity Level (SIL)
    2
  • Degree of pollution
    2
  • Conformance
    CE-compliant
  • Maximum altitude
    ≤ 2000 m (Above sea level)
  • Rated control circuit supply voltage US
    24 V DC -20 % / +20 % (provide external protection, typically 5 A)
  • Inrush current
    max. 2.5 A (Δt  1 ms)
  • Input voltage range "0" signal
    0 V DC ... 5 V DC
  • Max. permissible overall conductor resistance
    1.2 kΩ (Input and reset circuit at US)
  • Number of outputs
    8
  • Output voltage when switched off
    max. 0.1 V
  • Max. capacitive load
    max. 820 nF
  • Discharging circuit
    Yes, internal
  • Net weight
    159 g
  • Degree of protection
    IP20
  • Operating voltage display
    1 x green LED
  • Conductor cross-section AWG
    24 ... 12
  • Safety Integrity Level Claim Limit (SIL CL)
    3 (2-channel wiring)
  • Overvoltage category
    II
  • ECLASS 10.0.1
    27371819
  • Stop category
    0
  • Shock
    10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)
  • ECLASS 9.0
    27371819

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?