1104889 Phoenix Contact Electrical Safety Devices
Part#:1104889
Manufacturer:Phoenix Contact
Category:Electrical Safety Devices
Product Lifecycle:Active
Get a quick Quote!
Safe extension module with 8 safe inputs and 4 safe outputs, 4 reset inputs or 4 signal outputs, 4  clock outputs, TBUS interface, up to SILCL 3, Cat. 4/PL e, SIL 3, pluggable Push-in terminal block, TBUS connector included
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1104889 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 22.61 mm
- Max. permissible relative humidity (operation) 95 % (non-condensing)
- Indication 2 x LED (red)
- Ambient temperature (storage/transport) -20 °C ... 85 °C
- Maximum altitude ≤ 2000 m (Above sea level)
- Protective circuit Serial protection against polarity reversal
- Input voltage range "1" signal 11 VÂ DC ... 28.8 VÂ DC
- Number of outputs 4
- Nominal output voltage range 18.5 VÂ DC ... 28.1 VÂ DC (USÂ -Â 0,7Â V)
- Output voltage when switched off max. 0.1 V
- Discharging circuit Yes, internal
- Maximum inrush current 1.1 A (Δt = 3 s at Us)
- Response time see user manual
- Nominal operating mode 100% operating factor
- Protection class III (ENÂ 50178)
- Depth 113.6 mm
- Designation Air clearances and creepage distances between the power circuits
- Current consumption typ. 12 mA (typically with US)
- Description of the input configurable (as signal output or reset input)
- Max. permissible overall conductor resistance 1.2 kΩ (Input and reset circuit at US)
- Output name O1, O2, O3, O4
- Leakage current max. 100 µA
- Switching frequency max. 1/4 x tCycle [Hz]
- Conductor cross-section AWG 24 ... 16
- Performance level (PL) e (2-channel wiring)
- Standards/regulations ENÂ 50178
- Degree of pollution 2
- ECLASS 9.0 27371819
- Ambient temperature (operation) -10 °C ... 55 °C (observe derating)
- Power consumption at US typ. 1.08 W (Outputs inactive)
- Input voltage range "0" signal 0 VÂ DC ... 5 VÂ DC
- Cable length max. 100 m (per output)
- Nominal output voltage 24 VÂ DC (Supply via A1)
- Max. capacitive load max. 470 nF
- Test pulses ≤ 200 µs (Test pulse duration)
- Voltage 24 VÂ DC (via A1)
- Nominal voltage range 18.2 VÂ DC ... 27.8 VÂ DC (US - 1 V)
- Mounting type DIN rail mounting
- Assembly instructions Observe derating
- Housing material Polyamide PA non-reinforced
- Status display 1 x LED (green), 2 x LED (orange)
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Rated insulation voltage 250 VÂ AC
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- Conformance CE-compliant
- Height 107.74 mm
- Max. permissible humidity (storage/transport) 95 % (non-condensing)
- Rated control supply current IS typ. 45 mA (Outputs inactive)
- Inrush current max. 600 mA (Δt < 10 ms)
- Number of inputs 4
- Input current range "0" signal < 1 mA
- Protective circuit/component Suppressor diode
- Ohmic load min. 50 Ω (Observe limiting continuous current)
- Short-circuit protection Yes (self-limitation at 1.1Â A)
- Cycle time see user manual
- Net weight 141 g
- Degree of protection IP20
- Housing color yellow
- Connection method Push-in connection
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Safety Integrity Level Claim Limit (SIL CL) 3 (2-channel wiring)
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- ECLASS 11.0 27371819
- Rated control circuit supply voltage US 24 VÂ DC -20Â %Â /Â +20Â % (external fuse, typically 4Â A)
- Filter time 250 ms ±2 ms (Test pulse rate > 500 ms)
- Input name Reset inputs
- Output description PNP, IEC 61131-2 Typ 0,1
- Limiting continuous current 100 mA (per channel)
- Max. inductive load max. 2.4 mH
- Error detection time at 1-channel structure < 3.5 s (OFF state)
- Output voltage range 18.2 VÂ DC ... 27.8 VÂ DC (US - 1 V)
- Restart time min. 5 s (Boot time)
- Mounting position vertical or horizontal
- Min. degree of protection of inst. location IP54
- Operating voltage display 1 x green LED
- pluggable Yes
- Stripping length 10 mm
- Stop category 0
- Rated surge voltage/insulation Basic insulation 4Â kV between 24Â V power supply and I/Os to the housing
- Overvoltage category II
- Safety Integrity Level (SIL) 2
- Shock 10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)
- ECLASS 10.0.1 27371819
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?