Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/100 W
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1088851 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 55 mm
- Depth 84 mm
- Installation distance top/bottom 30 mm / 30 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Ambient temperature (start-up type tested) -40 °C
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Degree of pollution 2
- Frequency range (fN) 50 Hz ... 60 Hz 10 %
- Current consumption 2.1 A (100Â VÂ AC)
- Inrush current < 40 A (typical)
- Input fuse 4 A (slow-blow, internal)
- Type of protection Transient surge protection
- Nominal output voltage 24 V DC ±1 %
- Height 90 mm
- Installation distance right/left 0 mm / 0 mm
- Degree of protection IP20
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Protective circuit/component Varistor
- Power factor (cos phi) 0.47
- Feedback voltage resistance < 35 VÂ DC
- Nominal output current (IN) 4.2 A (-25 °C ... 55 °C)
- Residual ripple < 30 mVPP (with nominal values)
- Power loss nominal load max. < 11 W
- MTBF (IEC 61709, SN 29500) > 738000 h (40 °C)
- Protection class II (in closed control cabinet)
- Foot latch material POM (Polyoxymethylen)
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section AWG min. 24
- EMC requirements for noise immunity ENÂ 61000-6-1
- Stripping length 8 mm
- Standard - Electrical safety IECÂ 62368-1/VDEÂ 0805 (SELV)
- Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
- UL approvals UL/C-UL listed UL 508
- Criterion A Normal operating behavior within the specified limits.
- Derating 55 °C ... 70 °C (2.5%/K)
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Typical response time < 1 s
- Efficiency typ. 88 % (120Â VÂ AC)
- Insulation voltage input/output 4 kV AC (type test)
- Assembly instructions alignable: 0Â mm horizontally, 30Â mm vertically
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible min. 0.2 mm²
- Screw thread M3
- EMC requirements for noise emission ENÂ 61000-6-3
- Standard - Safety of transformers ENÂ 61558-2-16
- Standard - Safe isolation DINÂ VDEÂ 0100-410
- Mains variation/undervoltage ENÂ 61000-4-11
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Contact discharge 6 kV (Test Level 3)
- Comments Criterion A
- Connection in series yes
- Protection against overvoltage at the output (OVP) ≤ 35 V DC
- Output power 100 W
- Maximum power dissipation in no-load condition < 0.5 W
- Net weight 0.34 kg
- Housing material Polycarbonate
- Mounting position horizontal DIN rail NS 35, EN 60715
- Connection method Screw connection
- Conductor cross section flexible max. 2.5 mm²
- Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
- Nominal input voltage range 100 VÂ AC ... 240 VÂ AC
- Mains buffering time > 20 ms (120Â VÂ AC)
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Electrostatic discharge EN 61000-4-2
- Output 1 kV (Test Level 2 - symmetrical)
- ECLASS 10.0.1 27040701
- Nominal power consumption 242.6 VA
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Discharge in air 8 kV (Test Level 3)
- Test field strength 10 V/m
- Input 2 kV (Test Level 3 - symmetrical)
- Conducted interference ENÂ 61000-4-6
- ECLASS 9.0 27040701
- Climatic class 3K3 (in acc. with EN 60721)
- Input voltage range 85 VÂ AC ... 264 VÂ AC
- Conductor cross section AWG max. 14
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Frequency range 150 kHz ... 80 MHz
- Voltage 10 V (Test Level 3)
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27040701
- Voltage dips ENÂ 61000-4-11
- Budgetary standard IECÂ 60335-1
- Electromagnetic HF field ENÂ 61000-4-3
- Fast transients (burst) ENÂ 61000-4-4
- Surge voltage load (surge) ENÂ 61000-4-5
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?