Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 24 V DC/100 W

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1088851 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Width
    55 mm
  • Depth
    84 mm
  • Installation distance top/bottom
    30 mm / 30 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Ambient temperature (start-up type tested)
    -40 °C
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Degree of pollution
    2
  • Frequency range (fN)
    50 Hz ... 60 Hz 10 %
  • Current consumption
    2.1 A (100 V AC)
  • Inrush current
    < 40 A (typical)
  • Input fuse
    4 A (slow-blow, internal)
  • Type of protection
    Transient surge protection
  • Nominal output voltage
    24 V DC ±1 %
  • Height
    90 mm
  • Installation distance right/left
    0 mm / 0 mm
  • Degree of protection
    IP20
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Protective circuit/component
    Varistor
  • Power factor (cos phi)
    0.47
  • Feedback voltage resistance
    < 35 V DC
  • Nominal output current (IN)
    4.2 A (-25 °C ... 55 °C)
  • Residual ripple
    < 30 mVPP (with nominal values)
  • Power loss nominal load max.
    < 11 W
  • MTBF (IEC 61709, SN 29500)
    > 738000 h (40 °C)
  • Protection class
    II (in closed control cabinet)
  • Foot latch material
    POM (Polyoxymethylen)
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section AWG min.
    24
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Stripping length
    8 mm
  • Standard - Electrical safety
    IEC 62368-1/VDE 0805 (SELV)
  • Standard – Safety extra-low voltage
    IEC 62368-1 (SELV) und EN 60204-1 (PELV)
  • UL approvals
    UL/C-UL listed UL 508
  • Criterion A
    Normal operating behavior within the specified limits.
  • Derating
    55 °C ... 70 °C (2.5%/K)
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Typical response time
    < 1 s
  • Efficiency
    typ. 88 % (120 V AC)
  • Insulation voltage input/output
    4 kV AC (type test)
  • Assembly instructions
    alignable: 0 mm horizontally, 30 mm vertically
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible min.
    0.2 mm²
  • Screw thread
    M3
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard - Safety of transformers
    EN 61558-2-16
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Mains variation/undervoltage
    EN 61000-4-11
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Contact discharge
    6 kV (Test Level 3)
  • Comments
    Criterion A
  • Connection in series
    yes
  • Protection against overvoltage at the output (OVP)
    ≤ 35 V DC
  • Output power
    100 W
  • Maximum power dissipation in no-load condition
    < 0.5 W
  • Net weight
    0.34 kg
  • Housing material
    Polycarbonate
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Connection method
    Screw connection
  • Conductor cross section flexible max.
    2.5 mm²
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Mains buffering time
    > 20 ms (120 V AC)
  • Recommended breaker for input protection
    6 A ... 16 A (Characteristics B, C, D, K)
  • CSA
    CAN/CSA-C22.2 No. 60950-1-07
  • Electrostatic discharge
    EN 61000-4-2
  • Output
    1 kV (Test Level 2 - symmetrical)
  • ECLASS 10.0.1
    27040701
  • Nominal power consumption
    242.6 VA
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Discharge in air
    8 kV (Test Level 3)
  • Test field strength
    10 V/m
  • Input
    2 kV (Test Level 3 - symmetrical)
  • Conducted interference
    EN 61000-4-6
  • ECLASS 9.0
    27040701
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Input voltage range
    85 V AC ... 264 V AC
  • Conductor cross section AWG max.
    14
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Frequency range
    150 kHz ... 80 MHz
  • Voltage
    10 V (Test Level 3)
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 11.0
    27040701
  • Voltage dips
    EN 61000-4-11
  • Budgetary standard
    IEC 60335-1
  • Electromagnetic HF field
    EN 61000-4-3
  • Fast transients (burst)
    EN 61000-4-4
  • Surge voltage load (surge)
    EN 61000-4-5
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?