1086902 Phoenix Contact Programmable Logic Controllers
Part#:1086902
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline F XC, Digital output module, Digital outputs: 4, 21 V, 60 mA, connection method: 3-conductor, Extreme conditions version, Intrinsically safe, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1086902 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 129.9 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Degree of protection IP20
- Conductor cross section solid max. 1.5 mm²
- Note on weight specifications with connectors and bus base module
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Test section 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion A, supply lines DC: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 10.0.1 27242604
- Width 53.6 mm
- Ambient temperature (operation) -25 °C ... 60 °C (Standard)
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG min. 24
- Color traffic grey A RAL 7042
- Maximum altitude 3000 m
- Supply voltage 24 V DC
- Connection technology 3-conductor
- China RoHS Environmentally Friendly Use Period = 25;
- Utilization restriction Use in potentially explosive areas is not permitted in China.
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Designation Supply for digital output modules (UO)
- Mounting type DIN rail
- Net weight 0 g
- Number 2
- Output name Digital outputs
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Group C/IIB, IIIC
- ECLASS 11.0 27242604
- Depth 77.14 mm
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Conductor cross section flexible min. 0.2 mm²
- Stripping length 8 mm
- Mounting position any (no temperature derating)
- Current consumption max. 420 mA
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Connection method Push-in connection
- Conductor cross section flexible max. 1.5 mm²
- Conductor cross section AWG max. 16
- Transmission speed 100 Mbps
- Number of outputs 4
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion A, 6 kV contact discharge, 8 kV air discharge
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- IECEx IECEx UL 20.0044XEx ec [ia Ga] IIC T4 Gc[Ex ia Da] IIIC
- ECLASS 9.0 27242604
- ATEX DEMKO 20 ATEX 2370XII 3(1)G Ex ec [ia Ga] IIC T4 GcII (1)D [Ex ia Da] IIIC
- Output voltage 21 V
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- UL, USA/Canada Ind. Cont. Eq. (E238705) also ListedInd. Cont. Eq. for haz. loc. E196811Install in: Class I, Div. 2, Groups A, B, C, D T4Intrinsically safe outputs for: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III; [Ex ia] Haz locClass I, Zone 2, AEx e
- Nominal output voltage 21 V
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?