Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, Screw connection, input: 12 V DC - 24 V DC, output: 24 V DC / 2.5 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1066718 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight 0.246 kg
- Height 99 mm
- Power dissipation SLEEP MODE < 1 W
- Power loss nominal load max. < 8 W
- Degree of pollution 2
- EMC requirements for noise emission EN 61000-6-3
- Identification DNV GL
- Electromagnetic HF field EN 61000-4-3
- Comments Criterion A
- Input voltage range 9 V DC ... 24 V DC -25 % (SELV)
- Switch-on time < 1 s
- Inrush current integral (I2t) typ. 0.1 A2s
- Type test (IEC/EN 60950-1) B 4 kV DC
- Type test (IEC/EN 60950-1) D 0.5 kV DC
- Stripping length 8 mm
- Conductor cross section AWG 26 ... 14
- Nominal output current (IN) 2.5 A
- System deviation, static < 1 % (change in load, static 10 % ... 90 %)
- Residual ripple < 20 mVPP
- Feedback voltage resistance ≤ 35 V DC
- UOut > 0.9 x USet (LED lights up green)
- Time 320000 h
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Width 32 mm
- Efficiency typ. 92.1 % (24 V DC)
- Ambient temperature (start-up type tested) -40 °C
- Overvoltage category EN 61010-1 II (≤ 5000 m)
- Standards/regulations EN 61000-4-29
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Noise emission EN 55016
- Contact discharge 8 kV (Test Level 4)
- Electric strength, max. 35 V DC (60 s)
- Type test (IEC/EN 60950-1) A 2.6 kV DC
- Input fuse 15 A (fast blow, internal)
- Production test B 2 kV DC
- Conductor cross section solid 0.14 mm² ... 2.5 mm²
- Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) 0.2 mm² ... 2.5 mm²
- Nominal output voltage (UN) 24 V DC
- System deviation, dynamic < 2 % (Dynamic load change 10 % ... 90 %, 10 Hz)
- Short-circuit-proof yes
- Protection against overvoltage at the output (OVP) ≤ 32 V DC
- MTBF (IEC 61709, SN 29500) > 1347000 h (25 °C)
- Output current 5 A
- Protection class II
- Width with alternative assembly 90 mm
- Mains buffering typ. 16 ms (24 V DC)
- Typical current consumption typ. 7.2 A (12 V DC)
- Type test (IEC/EN 60950-1) C 0.5 kV DC
- Connection method Screw connection
- Production test D 0.5 kV DC
- Setting range of the output voltage (USet) 24 V DC ... 28 V DC (> 24 V DC, constant capacity)
- Static Boost (IStat.Boost) 3.125 A (≤ 40 °C)
- Dynamic Boost (IDyn.Boost) 5 A (≤ 60 °C (4,9 s))
- Connection in parallel Yes, for redundancy and increased capacity
- Rise time < 1 s (UOUT (10 % ... 90 %))
- Temperature 30 °C
- Main converter stage 70 kHz ... 150 kHz (Main converter stage)
- Degree of protection IP20
- Depth with alternative assembly 32 mm
- Maximum power dissipation in no-load condition < 1.3 W
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Climatic class 3K3 (in acc. with EN 60721)
- Designation Shipbuilding
- DNV GL conducted interference Class B
- Electrostatic discharge EN 61000-4-2
- Input 2 kV (symmetrical)
- Output 1 kV (Test Level 3 - symmetrical)
- I/O/S asymmetrical
- Test level 1 15 Hz 150 Hz (Test Level 3)
- Input, output (test level 2) 1 kHz (Test Level 2 - asymmetrical)
- Criterion A Normal operating behavior within the specified limits.
- Inrush current limitation typical 8.6 A
- Insulation voltage input/output 2.6 kV DC (type test)
- Production test A 1.2 kV DC
- Production test C 0.5 kV DC
- Flexible conductor cross section (ferrule with plastic sleeve) 0.25 mm² ... 2.5 mm²
- Conductor cross section flexible 0.14 mm² ... 2.5 mm²
- Magnetic circuit breaker tripping A1 ... A4 / B2 / C1 ... C2 / Z1 ... Z4
- System deviation, input voltage change < 0.1 % (change in input voltage ±10 %)
- No-load proof yes
- Connection in series yes
- POut > PThr (LED lights up yellow, output power > PThr, depending on the rotary selector switch setting)
- Voltage 1 kV
- Auxiliary converter stage 4 kHz ... 70 kHz (Auxiliary converter stage)
- Depth 90 mm
- Height with alternative assembly 99 mm
- Maximum altitude ≤ 5000 m (> 2000 m, observe derating)
- Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
- EMC requirements for noise immunity EN 61000-6-1
- EMC requirements, power plant IEC 61850-3
- DNV GL noise radiation Class B
- Frequency range 50 Hz ... 60 Hz
- Test field strength 1000 A/m
- Signal 2 kV (Test Level 4 - symmetrical)
- Voltage dip 0 %
- Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12
- Test level 6 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
- Signals (test level 1) 1 kHz (Test Level 2 - symmetrical)
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Vibration (operation) < 15 Hz, ±2.5 mm amplitude; 15 Hz ... 100 Hz: 2.3 g 90 Min. (in accordance with IEC 60068-2-6)
- Standard designation Mains variation/undervoltage
- Conducted noise emission EN 55016
- Additional text Test Level 2
- Fast transients (burst) EN 61000-4-4
- Conducted interference EN 61000-4-6
- Voltage dips EN 61000-4-11
- Pulse-shape magnetic field EN 61000-4-9
- Test level 5 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
- Attenuated oscillating wave EN 61000-4-18
- Signals (test level 2) 1 kHz (Test Level 2 - asymmetrical)
- Discharge in air 8 kV (Test Level 3)
- Surge voltage load (surge) EN 61000-4-5
- Frequency 60 Hz
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Test level 4 15 kHz 150 kHz (Test Level 3)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- Power frequency magnetic field EN 61000-4-8
- Number of periods 0.5 / 1 / 5 / 50 periods
- Test level 2 150 Hz 1.5 kHz (Test Level 3)
- Test level 3 1.5 kHz 15 kHz (Test Level 3)
- Input, output (test level 1) 1 kHz (Test Level 2 - symmetrical)
- ECLASS 9.0 27210901
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?