1066716 Phoenix Contact AC/DC Power Supplies

1066716 on Power Resource International
Phoenix Contact

Part#:1066716

Manufacturer:Phoenix Contact

Category:AC/DC Power Supplies

Product Lifecycle:Active

Get a quick Quote!

Primary-switched power supply unit, QUINT POWER, Push-in connection, input: 12 V DC - 24 V DC, output: 24 V DC / 1.3 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1066716 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Weight
    0.171 kg
  • Frequency
    60 Hz
  • Switch-on time
    < 1 s
  • Insulation voltage input/output
    1.5 kV DC (type test)
  • Connection method
    Push-in connection
  • Setting range of the output voltage (USet)
    24 V DC ... 28 V DC (> 24 V DC, constant capacity)
  • Output current
    2.5 A
  • Auxiliary converter stage
    4 kHz ... 70 kHz (Auxiliary converter stage)
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Ambient temperature (start-up type tested)
    -40 °C
  • Vibration (operation)
    < 15 Hz, ±2.5 mm amplitude; 15 Hz ... 100 Hz: 2.3 g 90 Min. (in accordance with IEC 60068-2-6)
  • Input voltage range
    12 V DC ... 24 V DC -25 % ... +33 %
  • Production test A
    3 kV AC
  • Conductor cross section AWG
    24 ... 14
  • Dynamic Boost (IDyn.Boost)
    2.6 A (≤ 60 °C (4,9 s))
  • Voltage
    300 V (1 s)
  • Protection class
    II
  • Shock
    18 ms, 30g, in each space direction (according to IEC 60068-2-27)
  • Overvoltage category EN 62477-1
    III (≤ 2000 m)
  • Standard designation
    Limitation of harmonic line currents
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Discharge in air
    8 kV (Test Level 3)
  • Electromagnetic HF field
    EN 61000-4-3
  • Frequency range
    50 Hz ... 60 Hz
  • Input
    2 kV (symmetrical)
  • Electric strength, max.
    35 V DC (60 s)
  • Inrush current limitation typical
    1.6 A
  • Type test (IEC/EN 60950-1) A
    4 kV AC
  • Nominal output current (IN)
    1.3 A
  • Feedback voltage resistance
    ≤ 35 V DC
  • MTBF (IEC 61709, SN 29500)
    > 1347000 h (25 °C)
  • Main converter stage
    70 kHz ... 150 kHz (Main converter stage)
  • Height
    106 mm
  • Maximum altitude
    ≤ 5000 m (> 2000 m, observe derating)
  • Standards/regulations
    EN 61000-3-2
  • Contact discharge
    8 kV (Test Level 4)
  • Test field strength
    1000 A/m
  • Fast transients (burst)
    EN 61000-4-4
  • I/O/S
    asymmetrical
  • Voltage dips
    EN 61000-4-11
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Test level 2
    16.67 Hz 50 Hz 60 Hz (Test Level 4)
  • Mains buffering
    typ. 2 ms (12 V DC)
  • Typical response time
    700 ms (from SLEEP MODE)
  • Input fuse
    15 A (fast blow, internal)
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Nominal output voltage (UN)
    24 V DC
  • Protection against overvoltage at the output (OVP)
    < 32 V DC
  • Time
    432000 h
  • Width
    22.5 mm
  • Depth
    90 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Overvoltage category EN 61010-1
    II (≤ 5000 m)
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Conducted noise emission
    EN 55016
  • Electrostatic discharge
    EN 61000-4-2
  • Noise emission
    EN 55016
  • Signal
    2 kV (Test Level 4 - symmetrical)
  • Power frequency magnetic field
    EN 61000-4-8
  • Conducted interference
    EN 61000-4-6
  • Number of periods
    0.5 / 1 / 5 / 50 periods
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • Test level 1
    16.67 Hz 50 Hz 60 Hz (Test Level 3)
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • Typical current consumption
    typ. 3.75 A (12 V DC)
  • Inrush current integral (I2t)
    < 0.1 A2s
  • Stripping length
    10 mm
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Static Boost (IStat.Boost)
    1.625 A (≤ 40 °C)
  • Temperature
    25 °C
  • Degree of protection
    IP20
  • Efficiency
    typ. 90.4 % (12 V DC)
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of pollution
    2
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Designation
    SIQ
  • Identification
    CB scheme (IEC 61010-1, IEC 61010-2-201)
  • Comments
    Criterion B
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Surge voltage load (surge)
    EN 61000-4-5
  • Additional text
    Test Level 2
  • Voltage dip
    0 %
  • Criterion A
    Normal operating behavior within the specified limits.
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Attenuated oscillating wave
    EN 61000-4-18
  • ECLASS 9.0
    27210901

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?