Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, Push-in connection, input: 12 V DC - 24 V DC, output: 12 V DC / 2.5 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1066704 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight 0.173 kg
- Connection method Push-in connection
- Conductor cross section AWG 24 ... 14
- Setting range of the output voltage (USet) 5 V DC ... 15 V DC (> 12 V DC, constant capacity)
- Output current 2.5 A
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Depth 90 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of pollution 2
- Standard - Safe isolation IEC 61558-2-16
- Input voltage range 12 V DC ... 24 V DC -25 % ... +33 % (SELV)
- Inrush current limitation typical 1.5 A (after 1 ms)
- Production test A 3 kV AC
- Static Boost (IStat.Boost) 3.125 A (≤ 40 °C)
- MTBF (IEC 61709, SN 29500) > 1347000 h (25 °C)
- Voltage 300 V (1 s)
- Main converter stage 70 kHz ... 150 kHz (Main converter stage)
- Height 106 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Maximum altitude ≤ 5000 m (> 2000 m, observe derating)
- Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
- Overvoltage category EN 61010-1 II (≤ 5000 m)
- Standard – Safety extra-low voltage IEC 61010-1 (SELV)
- Electrostatic discharge EN 61000-4-2
- Test field strength 1000 A/m
- Fast transients (burst) EN 61000-4-4
- I/O/S asymmetrical
- Additional text Test Level 2
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Attenuated oscillating wave EN 61000-4-18
- ECLASS 9.0 27210901
- Mains buffering typ. 3 ms (12 V DC)
- Insulation voltage input/output 2.6 kV DC (type test)
- Stripping length 10 mm
- Nominal output voltage (UN) 12 V DC
- Feedback voltage resistance ≤ 25 V DC
- Auxiliary converter stage 4 kHz ... 70 kHz (Auxiliary converter stage)
- Width 22.5 mm
- Climatic class 3K3 (in acc. with EN 60721)
- Typical current consumption typ. 3.55 A (12 V DC)
- Input fuse 15 A (fast blow, internal)
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Dynamic Boost (IDyn.Boost) 5 A (≤ 60 °C (4,9 s))
- Temperature 25 °C
- Degree of protection IP20
- Hood version Polycarbonate
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- EMC requirements for noise immunity EN 61000-6-1
- Standard - Electrical safety IEC 61010-2-201 (SELV)
- Standard - safety for equipment for measurement, control, and laboratory use IEC 61010-1
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Noise emission EN 55016
- Discharge in air 8 kV (Test Level 3)
- Frequency range 50 Hz ... 60 Hz
- Surge voltage load (surge) EN 61000-4-5
- Frequency 60 Hz
- Voltage dip 0 %
- Pulse-shape magnetic field EN 61000-4-9
- Criterion A Normal operating behavior within the specified limits.
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- Inrush current integral (I2t) typ. 0.05 A2s
- Type test (IEC/EN 60950-1) A 4 kV AC
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Nominal output current (IN) 2.5 A
- Protection against overvoltage at the output (OVP) ≤ 18 V DC
- Time 432000 h
- Protection class II
- Efficiency typ. 91.1 % (12 V DC)
- Ambient temperature (start-up type tested) -40 °C
- Vibration (operation) < 15 Hz, ±2.5 mm amplitude; 15 Hz ... 100 Hz: 2.3 g 90 Min. (in accordance with IEC 60068-2-6)
- Standard - Safety of transformers EN 61558-2-16
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Contact discharge 8 kV (Test Level 4)
- Comments Criterion B
- Output 1 kV (Test Level 3 - symmetrical)
- Signal 2 kV (Test Level 4 - symmetrical)
- Voltage dips EN 61000-4-11
- Test level 1 16.67 Hz 50 Hz 60 Hz (Test Level 3)
- Test level 2 16.67 Hz 50 Hz 60 Hz (Test Level 4)
- Conducted noise emission EN 55016
- Electromagnetic HF field EN 61000-4-3
- Input 2 kV (symmetrical)
- Conducted interference EN 61000-4-6
- Power frequency magnetic field EN 61000-4-8
- Number of periods 0.5 / 1 / 5 / 50 periods
- Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?