TRIO POWER primary-switched power supply in IP67 die-cast housing, input: 1-phase, output: 24 V DC / 8 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1065976 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth 53 mm
- Ambient temperature (operation) -25 °C ... 70 °C (Derating >60°C: 2.5 %/K)
- Degree of pollution 3
- Height 240 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Permissible humidity (operation) ≤ 100 % (at 25 °C, non-condensing)
- Nominal input voltage range 100 V AC ... 240 V AC
- Current consumption 2.2 A (100 V AC)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of protection IP67
- Ambient temperature (start-up type tested) -25 °C
- Input voltage range 100 V AC ... 240 V AC 10 %
- Discharge current to PE < 3.5 mA
- Nominal power consumption 285 VA
- Protective circuit/component Varistor
- Derating > 60 °C ... 70 °C (2.5%/K)
- Connection in parallel no
- Output power 192 W
- Power loss nominal load max. < 18 W (120 V AC)
- Protection class I
- Standards/regulations EN/IEC 60529
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Electrostatic discharge EN 61000-4-2
- Electromagnetic HF field EN 61000-4-3
- Output 1 kV (Test Level 3 - symmetrical)
- Voltage dip 0 %
- Frequency 50 Hz
- REACh SVHC Lead 7439-92-1
- Width 136 mm
- Max. permissible relative humidity (operation) ≤ 100 % (at 25 °C, non-condensing)
- Climatic class 3K3 (in acc. with EN 60721)
- AC frequency range 50 Hz ... 60 Hz ±10 %
- Inrush current ≤ 25 A (typical)
- Frequency range (fN) 50 Hz ... 60 Hz ±10 %
- Input fuse 6.3 A (internal (device protection))
- Type of protection Transient surge protection
- Nominal output voltage 24 V DC ±1 %
- Feedback voltage resistance ≤ 35 V DC
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Efficiency typ. 91 % (120 V AC)
- Insulation voltage input/output 3 kV AC (type test)
- Standard designation Degrees of protection provided by enclosures (IP code)
- Conducted noise emission EN 55016
- Noise emission EN 55016
- Test field strength 10 V/m (Test Level 3)
- Voltage 230 V AC
- Surge voltage load (surge) EN 61000-4-5
- Number of periods 1 period
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- Installation height ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
- Dielectric strength maximum ≤ 300 V AC 15 s
- Mains buffering time > 15 ms (120 V AC)
- Power factor (cos phi) 0.93
- Nominal output current (IN) 8 A
- Connection in series No
- Maximum power dissipation in no-load condition < 8 W (120 V AC)
- MTBF (IEC 61709, SN 29500) > 1800000 h (25 °C)
- Assembly instructions Alignable: 20 mm horizontally, 50 mm vertically above, 100 mm vertically below
- Type of locking screw locking
- Harmonic currents EN 61000-3-2
- Contact discharge 6 kV (Test Level 3)
- Comments Criterion A
- Signal 1 kV (Test Level 2 - asymmetrical)
- Voltage dips EN 61000-4-11
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 9.0 27040701
- Recommended breaker for input protection 6 A ... 16 A (US/CAN: branch circuit protection < 20 A) (Characteristic B, C, D, K or comparable)
- Dynamic Boost (IDyn.Boost) 12 A (5 s)
- Protection against overvoltage at the output (OVP) ≤ 30 V DC
- Residual ripple ≤ 10 mVPP
- Net weight 1.5 kg
- Connection method 7/8″ circular connector
- Range of positions 4 Socket
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Frequency range 0.15 MHz ... 80 MHz
- Input 2 kV (Test Level 4 - symmetrical)
- Fast transients (burst) EN 61000-4-4
- Conducted interference EN 61000-4-6
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?