Primary-switched power supply unit, TRIO POWER, Snap-on connection, Cross Power System - installation, input: 3-phase, output: 24 V DC / 5 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1064922 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Installation distance top/bottom 50 mm / 50 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Discharge current to PE < 0.25 mA
- Current consumption 3x 0.4 A (400 V AC)
- Power factor (cos phi) 0.55
- Protection against overvoltage at the output (OVP) ≤ 30 V DC
- Output power 120 W
- Efficiency typ. 91 % (400 V AC)
- Insulation voltage input/output 3 kV AC (type test)
- Conductor cross section flexible min. 0.2 mm²
- EMC requirements for noise immunity EN 61000-6-2
- Standard - Electrical safety IEC 61010-1 (SELV)
- UL approvals UL Listed UL 61010-2-201
- Electrostatic discharge EN 61000-4-2
- Frequency range 80 MHz ... 6 GHz
- Comments Criterion A
- Frequency 50 Hz
- Additional text Test Level 2
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ETIM 6.0 EC002540
- Width 36 mm
- Installation distance right/left (active) 14 mm / 14 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Degree of pollution 2
- Nominal power consumption 243.6 VA
- Mains buffering time typ. 20 ms (400 V AC)
- Connection in parallel Yes, for redundancy and increased capacity
- Typical response time < 1 s
- Power loss nominal load max. < 12 W (480 V AC)
- Connection method Push-in connection
- Conductor cross section AWG max. 16
- Standard – Safety extra-low voltage IEC 61010 (SELV) / (PELV)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Conducted noise emission EN 55016
- Test field strength 10 V/m (Test Level 3)
- Input 3 kV (Test Level 3 - symmetrical)
- Signal 1 kV (Test Level 1 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 10.0.1 27040701
- ECLASS 11.0 27040701
- ECLASS 9.0 27040701
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Installation distance top/bottom (active) 50 mm / 50 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Installation height ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
- Protective circuit/component Varistor
- Setting range of the output voltage (USet) 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
- Connection in series yes
- Residual ripple ≤ 20 mVPP
- MTBF (IEC 61709, SN 29500) > 2300000 h (25 °C)
- Conductor cross section solid max. 1.5 mm²
- Conductor cross section AWG min. 24
- Standard - Safe isolation DIN VDE 0100-410
- Height 160 mm
- Installation distance right/left 0 mm / 0 mm
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Nominal input voltage range 3x 400 V AC ... 500 V AC
- AC frequency range 50 Hz ... 60 Hz
- Input fuse 3.15 A (internal (device protection), slow-blow)
- Nominal output current (IN) 5 A
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Net weight 0.7 kg
- Protection class II (in closed control cabinet)
- Conductor cross section solid min. 0.2 mm²
- Stripping length 8 mm
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Noise emission EN 55016
- Discharge in air 8 kV (Test Level 4)
- Output 1 kV (Test Level 2 - symmetrical)
- Voltage dip 0 %
- Voltage 230 V AC
- Number of periods 1 period
- REACh SVHC Lead 7439-92-1
- ETIM 7.0 EC002540
- Depth 159 mm
- Degree of protection IP20
- Climatic class 3K3 (in acc. with EN 60721)
- Input voltage range 3x 400 V AC ... 500 V AC -20 % ....+15 %
- Type of protection Transient surge protection
- Nominal output voltage 24 V DC ±1 %
- Dynamic Boost (IDyn.Boost) 7.5 A (5 s)
- Derating > 60 °C ... 70 °C (2.5%/K)
- Maximum power dissipation in no-load condition < 1 W (400 V AC)
- Assembly instructions Cross Power System
- Conductor cross section flexible max. 1.5 mm²
- Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only)
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Contact discharge 6 kV (Test Level 4)
- Electromagnetic HF field EN 61000-4-3
- Fast transients (burst) EN 61000-4-4
- Conducted interference EN 61000-6-2
- Voltage dips EN 61000-4-11
- ECLASS 6.0 27049000
- ECLASS 7.0 27049002
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?