1052652 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:1052652
Manufacturer:Phoenix Contact
Category:Electrical Measuring & Monitoring Instruments
Product Lifecycle:Active
Get a quick Quote!
Ex i temperature transducer: converts signals from resistance temperature detectors installed in the Ex area and transmits a 0/4 - 20 mA signal to a load in the safe area. Freely programmable, 3-way isolation, SIL, Push-in connection, order configuration.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1052652 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (operation) 49 °C
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Electromagnetic compatibility Conformance with EMC directive
- Color gray
- Max. output power Po 350 mW
- Altitude ≤ 5000 m
- Potentiometer resistance range 0 Ω ... 50 kΩ
- Configurable/programmable Yes
- Signal output Current output
- Nominal supply voltage 24 V DC
- Connection method Push-in connection
- Transmission error, typical 0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
- Input current Ii 100 mA
- IECEx [Ex ia Ma] I
- DNV GL-Humidity B
- Certificate RU C-DE.AB72.B.00093/19
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 27210120
- ECLASS 7.0 27210120
- ECLASS 9.0 27210129
- Temperature coefficient, typical 0.01 %/K
- Status display Green LED (supply voltage, PWR)
- Housing material PA 6.6-FR
- Degree of pollution 2
- Depth 114.5 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Rated insulation voltage 300 Vrms
- Temperature measuring range -200 °C ... 850 °C (Range depending on the sensor type)
- Max. permissible overall conductor resistance 50 Ω (Per cable)
- Load/output load current output ≤ 600 Ω
- Power dissipation ≤ 0.76 W
- Conductor cross section solid 0.2 mm² ... 1.5 mm²
- Conductor cross section AWG 24 ... 16
- Designation EAC Ex
- Overvoltage category II
- Electrical isolation 375 V (Peak value in accordance with IEC/EN 60079-11)
- Width 12.5 mm
- Ambient temperature (storage/transport) -40 °C ... 80 °C
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Sensor input current 10 µA ... 210 µA (Up to 2x 210 µA with 3-conductor technology)
- Behavior in the event of a sensor error As per NE 43 or can be freely defined
- Stripping length 8 mm
- Alignment zero ± 5 %
- Output ripple (current) < 15 µAPP
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Alignment span ± 5 %
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- Max. output voltage Uo 3.5 V
- Max. external inductivity Lo 20 µH
- Standards/regulations GB 3626.20
- Height 116 mm
- Degree of protection IP20
- Measuring range span ≥ 50 K
- Step response (0–99%) typ. 1 s
- DNV GL-EMC B
- Sensor types (RTD) that can be used Sensors (2-, 3-, 4-conductor)
- Input signal range 0 Ω ... 50 kΩ
- Current output signal 0 mA ... 20 mA
- Supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
- Power consumption ≤ 1 W
- No. of channels 1
- UNSPSC 20.0 41112105
- ETIM 6.0 EC002919
- UNSPSC 11 39121008
- UNSPSC 12.01 39121008
- UNSPSC 21.0 41112105
- Max. internal capacitance Ci 47 µF
- Input power Pi 550 mW
- Additional text and EN 61326
- Interference emission EN 61000-6-4
- Max. output current Io 400 mA
- Group IIC/IIB/IIA
- Input voltage Ui 7 V
- Conformance CE-compliant, additionally EN 61326
- DNV GL-Temperature B
- DNV GL-Vibration A
- Vibration A
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 4.0 27210120
- ECLASS 6.0 27210120
- ETIM 4.0 EC001446
- UNSPSC 7.0901 39121008
- Safety-related maximum voltage Um 253 V AC (125 V DC, Zone 2: 3.1, 3.2 = 30 V DC)
- Noise emission EN 61000-6-4
- Typical deviation from the measuring range final value 1 %
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- Humidity B
- Temperature B
- ECLASS 5.1 27210120
- ETIM 3.0 EC001446
- Max. external capacitance Co 2 µF
- ATEX I (M1) [Ex ia Ma] I
- Identification [Ex ia Ga] IIC
- EMC B
- ECLASS 5.0 27210120
- UNSPSC 19.0 41112105
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 10.0.1 27210129
- ECLASS 11.0 27210129
- ETIM 2.0 EC001446
- ETIM 7.0 EC002919
- UNSPSC 13.2 41112105
- UNSPSC 6.01 30211506
- UNSPSC 18.0 41112105
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?