1052427 Phoenix Contact Programmable Logic Controllers

1052427 on Power Resource International
Phoenix Contact

Part#:1052427

Manufacturer:Phoenix Contact

Category:Programmable Logic Controllers

Product Lifecycle:Active

Get a quick Quote!

Axioline F XC, Digital input module, Digital inputs: 16 (NAMUR), 8 V DC, connection method: 2-conductor, Extreme conditions version, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connec

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1052427 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • ECLASS 11.0
    27242604
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Connection method
    Push-in connection
  • Conductor cross section AWG max.
    16
  • Net weight
    390.9 g
  • Input name
    Digital inputs
  • Number of inputs
    16 (NAMUR)
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • Mechanical tests
    Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
  • Utilization restriction
    Use in potentially explosive areas is not permitted in China.
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible max.
    1.5 mm²
  • Stripping length
    8 mm
  • Transmission speed
    100 Mbps
  • Description of the input
    NAMUR enabled digital input signals
  • UL, USA/Canada
    Class I, Div. 2, Groups A, B, C, D T4
  • Width
    53.6 mm
  • Note on dimensions
    The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
  • Note on the connection method
    Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
  • Conductor cross section flexible min.
    0.2 mm²
  • Color
    traffic grey A RAL 7042
  • Maximum altitude
    3000 m
  • Current consumption
    max. 130 mA
  • Connection technology
    2-conductor
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
  • IECEx
    IECEx UL 20.0002XEx ec IIC T4 Gc
  • ECLASS 10.0.1
    27242604
  • Height
    126.1 mm
  • Ambient temperature (operation)
    -25 °C ... 60 °C (Standard)
  • Designation
    Supply for digital input modules (UI)
  • Degree of protection
    IP20
  • Conductor cross section AWG min.
    24
  • Mounting position
    any (no temperature derating)
  • Number
    2
  • Supply voltage range
    19.2 V DC ... 30 V DC (including all tolerances, including ripple)
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion A, 6 kV contact discharge, 8 kV air discharge
  • ATEX
    DEMKO 20 ATEX 2334XII 3G Ex ec IIC T4 Gc
  • Depth
    77.14 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Conductor cross section solid max.
    1.5 mm²
  • Mounting type
    DIN rail
  • Note on weight specifications
    with connectors and bus base module
  • Supply voltage
    24 V DC
  • Nominal input voltage UIN
    8.2 V DC
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion A, supply lines DC: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables
  • Interference emission
    Noise emission test as per EN 61000-6-4 Class A
  • REACh SVHC
    Lead 7439-92-1
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • Test section
    5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
  • ECLASS 9.0
    27242604
  • Protection class
    III (IEC 61140, EN 61140, VDE 0140-1)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?