1052417 Phoenix Contact Programmable Logic Controllers

1052417 on Power Resource International
Phoenix Contact

Part#:1052417

Manufacturer:Phoenix Contact

Category:Programmable Logic Controllers

Product Lifecycle:Active

Get a quick Quote!

Axioline P EX, Digital input module, Digital inputs: 16 (NAMUR), 8 V DC, connection method: 2-conductor, Intrinsically safe, transmission speed in the local bus: 100 Mbps, degree of protection: IP20

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1052417 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Note on dimensions
    The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
  • Width
    53.6 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Degree of protection
    IP20
  • Conductor cross section solid min.
    0.2 mm²
  • Mounting type
    DIN rail
  • Stripping length
    8 mm
  • Note on weight specifications
    with connectors and bus base module
  • Supply voltage
    5 V DC (via bus base module)
  • Number of inputs
    16 (NAMUR)
  • Group
    A, B / IIC
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
  • REACh SVHC
    Lead 7439-92-1
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • Height
    126.1 mm
  • Ambient temperature (operation)
    -40 °C ... 70 °C (Standard)
  • Connection method
    Push-in connection
  • Conductor cross section solid max.
    1.5 mm²
  • Conductor cross section flexible min.
    0.2 mm²
  • Net weight
    409.1 g
  • Maximum altitude
    2000 m
  • Description of the input
    NAMUR enabled digital input signals
  • Test section
    5 V supply of the local bus (UBus) / functional ground 500 V AC 62 Hz 1 min.
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion A, supply lines DC: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables
  • IECEx
    IECEx UL 20.0044XEx ec [ia Ga] IIC T4 Gc[Ex ia Da] IIIC
  • ATEX
    DEMKO 20 ATEX 2370XII 3(1)G Ex ec [ia Ga] IIC T4 GcII (1)D [Ex ia Da] IIIC
  • ECLASS 10.0.1
    27242604
  • Current consumption
    max. 135 mA
  • Connection technology
    2-conductor
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • Interference emission
    Noise emission test as per EN 61000-6-4 Class A
  • Protection class
    III (IEC 61140, EN 61140, VDE 0140-1)
  • ECLASS 11.0
    27242604
  • Depth
    77.14 mm
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 2000 m above sea level)
  • Designation
    Supply of the Axioline P local bus UBus
  • Conductor cross section AWG min.
    24
  • Conductor cross section flexible max.
    1.5 mm²
  • Color
    traffic grey A RAL 7042
  • Transmission speed
    100 Mbps
  • Overvoltage category
    II
  • ECLASS 9.0
    27242604
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 2000 m above sea level)
  • Note on the connection method
    Please observe the information provided on conductor cross sections in the “Axioline P: system and installation” user manual.
  • Conductor cross section AWG max.
    16
  • Degree of pollution
    2
  • Supply voltage range
    19.2 V DC ... 30 V DC (via bus base module (UL) at AXL P BK...)
  • Input name
    Digital inputs
  • Protective circuit
    Polarity reversal protection of the inputs
  • Nominal input voltage UIN
    8.2 V DC
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • UL, USA/Canada
    Ind. Cont. Eq. (E238705) also ListedInd. Cont. Eq. for haz. loc. E196811Install in: Class I, Div. 2, Groups A, B, C, D T4Intrinsically safe outputs for: Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III; [Ex ia] Haz locClass I, Zone 2, AEx e

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?