1046993 Phoenix Contact Terminal Blocks
Part#:1046993
Manufacturer:Phoenix Contact
Category:Terminal Blocks
Product Lifecycle:Active
Get a quick Quote!
Distribution block, nominal current: 41 A, connection method: Push-in connection, Push-in connection, number of connections: 13, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, width: 31.4 mm, color: violet, mounting type: NS 15
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1046993 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Number of connections 13
- Color violet
- Maximum load current 22 A (with a 2.5 mm² conductor cross section)
- Nominal current IN 17.5 A
- Finger protection guaranteed
- Bending test turns 135
- Tight fit on carrier NS 35/NS 15
- Conductor cross section short circuit testing 2.5 mm²
- Result of aging test Test passed
- Nominal cross section 1.5 mm²
- Degree of pollution 3
- Maximum total current 32 A
- Result of surge voltage test Test passed
- Result of flexion and pull-out test Test passed
- Tensile test result Test passed
- Result of temperature-rise test Test passed
- Result of thermal test Test passed
- Oscillation, broadband noise test result Test passed
- Acceleration 30g
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2018-05
- Shock duration 18 ms
- Connection in acc. with standard IEC 60947-7-1
- Conductor cross section flexible min. 0.14 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 1.5 mm²
- Connection cross sections directly pluggable 0.34 mm² 2.5 mm²
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 11.0 27141120
- ETIM 7.0 EC000897
- Number of levels 1
- Flammability rating according to UL 94 V0
- Overvoltage category III
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Bending test rotation speed 10 rpm
- Result of voltage-drop test Test passed
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Shock form Half-sine
- Surface flammability NFPA 130 (ASTM E 162) passed
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Width 31.4 mm
- Connection method Push-in connection
- Conductor cross section flexible max. 1.5 mm²
- Value 0.34 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- ECLASS 9.0 27141120
- Nominal cross section feed-in 4 mm²
- Insulating material group I
- Open side panel No
- Back of the hand protection guaranteed
- Result of power-frequency withstand voltage test Test passed
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Result of tight fit on support Test passed
- Setpoint 5 N
- Short-time current 0.3 kA
- Short circuit stability result Test passed
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Height NS 15 27.4 mm
- Conductor cross section solid min. 0.34 mm²
- Min. AWG conductor cross section, flexible 26
- Conductor cross section flexible, with ferrule with plastic sleeve max. 1.5 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.14 mm²
- ETIM 6.0 EC000897
- Insulating material PA
- Rated surge voltage 6 kV
- Nominal voltage UN 500 V
- Power frequency withstand voltage setpoint 1.89 kV
- Bending test conductor cross section/weight 0.2 mm² / 0.2 kg
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Ageing test for screwless modular terminal block temperature cycles 192
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Length 21.6 mm
- Conductor cross section AWG min. 26
- Conductor cross section AWG max. 14
- Max. AWG conductor cross section, flexible 14
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- Ambient temperature (actuation) -5 °C ... 70 °C
- Connection Pick-off level
- Stripping length 8 mm ... 10 mm
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.14 mm²
- Internal cylindrical gage A3
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 10.0.1 27141120
- Shock test result Test passed
- Number of shocks per direction 3
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2018-05
- ASD level 6.12 (m/s2)2/Hz
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Test spectrum Service life test category 2, bogie-mounted
- Test duration per axis 5 h
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?