1043418 Phoenix Contact Redundancy Modules
Part#:1043418
Manufacturer:Phoenix Contact
Category:Redundancy Modules
Product Lifecycle:Active
Get a quick Quote!
Active QUINT single redundancy module for DIN rail mounting, protective coating, input: 12 - 24 V DC, output: 12 - 24 V DC/1 x 40 A, incl. mounted UTA 107/30 universal DIN rail adapter
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Redundancy Modules that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1043418 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth 125 mm
- Ambient temperature (operation) -40 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Max. permissible relative humidity (operation) ≤ 100 % (at 25 °C, non-condensing)
- Current consumption 40 A
- Selective Fuse Breaking (ISFB) 215 A (15 ms)
- Net weight 0.4 kg
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Stripping length 8 mm
- EMC requirements for noise immunity EN 61000-6-1
- Conducted noise emission EN 55016
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electrostatic discharge EN 61000-4-2
- Frequency range 0.15 MHz ... 80 MHz
- I/O/S asymmetrical
- Frequency 16.67 Hz
- ETIM 7.0 EC000683
- Width with alternative assembly 122 mm
- Installation distance top/bottom 50 mm / 50 mm
- Degree of pollution 2
- Nominal input current 40 A (-40 °C ... 60 °C)
- Output voltage range 8 V DC ... 27.5 V DC
- Protection against overvoltage at the output (OVP) ≤ 30 V DC
- Protection class III
- Connection method Push-in connection
- Conductor cross section AWG min. 24
- Conductor cross section AWG max. 16
- Height 130 mm
- Installation distance right/left 0 mm / 0 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- Nominal output current (IN) 40 A
- Dynamic Boost (IDyn.Boost) 60 A (5 s)
- Connection in series No
- Housing material Aluminum / stainless steel
- Conductor cross section solid max. 1.5 mm²
- EMC requirements for noise emission EN 61000-6-3
- Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- DNV GL noise radiation Class B
- Contact discharge 8 kV (Test Level 4)
- Fast transients (burst) EN 61000-4-4
- Voltage 10 V (Test Level 3)
- Power frequency magnetic field EN 61000-4-8
- ECLASS 10.0.1 27371010
- Height with alternative assembly 130 mm
- Degree of protection IP20
- Climatic class 3K3 (in acc. with EN 60721)
- Nominal input voltage range 12 V DC ... 24 V DC
- Derating 60 °C ... 70 °C (2.5%/K)
- MTBF (IEC 61709, SN 29500) > 13486000 h (25 °C)
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible max. 1.5 mm²
- Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
- Standard - Safe isolation DIN VDE 0100-410
- Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment EN 50178
- Additional text 60 s
- Discharge in air 15 kV (Test Level 4)
- Test field strength 30 A/m
- Signal 1 kV (Test Level 2 - asymmetrical)
- Conducted interference EN 61000-4-6
- REACh SVHC Lead 7439-92-1
- Width 32 mm
- Depth with alternative assembly 35 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Input voltage range 8 V DC ... 27.5 V DC (SELV)
- Static Boost (IStat.Boost) 45 A
- Power loss nominal load max. 6.5 W (IOUT = 40 A)
- Efficiency typ. 99 % (12 V DC)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section flexible min. 0.2 mm²
- Screw thread M4
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Noise emission EN 55016
- Electromagnetic HF field EN 61000-4-3
- Output 1 kV (Test Level 2 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 11.0 27371010
- ETIM 6.0 EC000683
- UL approvals UL/C-UL listed UL 508
- DNV GL conducted interference Class A
- Comments Criterion A
- Input 1 kV (Test Level 4 - symmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 9.0 27371010
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?