1035430 Phoenix Contact Programmable Logic Controllers
Part#:1035430
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline F XC, Temperature recording module, Analog inputs: 4 (for resistance temperature detectors), connection method: 2-, 3-, 4-conductor (shielded), transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20,
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1035430 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Conductor cross section AWG max. 16
- Current consumption max. 17 mA
- Power consumption max. 1.1 W (at UBus and UA)
- Protective circuit Surge protection electronic (35 V, 0.5 s)
- ETIM 7.0 EC001596
- ECLASS 7.0 27242601
- Connection technology 2-, 3-, 4-conductor (shielded)
- Height 126.1 mm
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- Conductor cross section solid min. 0.2 mm²
- Color traffic grey A RAL 7042
- Data formats IB IL, S7-compatible
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- ATEX II 3 G Ex ec IIC T4 Gc
- UL, USA/Canada cULus
- ECLASS 11.0 27242601
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 6.0 27242600
- Depth 54 mm
- Ambient temperature (operation) -25 °C ... 60 °C (Standard, applications with UL approval, use in zone 2 potentially explosive area)
- Designation Supply for analog modules (UA)
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section AWG min. 24
- Degree of pollution 2 (IEC 60664-1, EN 60664-1)
- Transmission speed 100 Mbps
- Number of inputs 4 (for resistance temperature detectors)
- Sensor types (RTD) that can be used Pt, Ni, KTY, Cu sensors
- Linear resistance measuring range 0 Ω ... 500 Ω
- Measured value representation 16 bits (15 bits + sign bit)
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Caption Dimensional drawing
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Connection method Spring-cage connection with direct connector-in method
- Conductor cross section solid max. 1.5 mm²
- Mounting type DIN rail
- Net weight 144 g
- Note on weight specifications with connectors and bus base module
- Supply voltage 24 V DC
- Input name Analog inputs
- A/D converter resolution 24 bit
- Input filter time 40 ms
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Width 35 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Degree of protection IP20
- Conductor cross section flexible max. 1.5 mm²
- Stripping length 8 mm
- Mounting position any (no temperature derating)
- Number of interfaces 2
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Description of the input Inputs for resistive temperature sensors
- Nominal value of the current sources 1 mA (Pt 100, Ni 100, RLin 500 Ω; pulse current, the specification is valid during the sampling phase)
- Type of protection Short-circuit protection, overload protection of the inputs
- Test section 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- IECEx Ex ec IIC T4 Gc
- ECLASS 10.0.1 27242601
- ETIM 6.0 EC001596
- Overvoltage category II (IEC 60664-1, EN 60664-1)
- ECLASS 9.0 27242601
- REACh SVHC Lead 7439-92-1
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?