Axioline F XC, Temperature recording module, Analog inputs: 4 (for resistance temperature detectors), connection method: 2-, 3-, 4-conductor (shielded), transmission speed in the local bus: 100 Mbps, Extreme conditions version, degree of protection: IP20,

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1035430 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Conductor cross section AWG max.
    16
  • Current consumption
    max. 17 mA
  • Power consumption
    max. 1.1 W (at UBus and UA)
  • Protective circuit
    Surge protection electronic (35 V, 0.5 s)
  • ETIM 7.0
    EC001596
  • ECLASS 7.0
    27242601
  • Connection technology
    2-, 3-, 4-conductor (shielded)
  • Height
    126.1 mm
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Note on the connection method
    Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
  • Conductor cross section solid min.
    0.2 mm²
  • Color
    traffic grey A RAL 7042
  • Data formats
    IB IL, S7-compatible
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
  • ATEX
     II 3 G Ex ec IIC T4 Gc
  • UL, USA/Canada
    cULus
  • ECLASS 11.0
    27242601
  • Protection class
    III (IEC 61140, EN 61140, VDE 0140-1)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 6.0
    27242600
  • Depth
    54 mm
  • Ambient temperature (operation)
    -25 °C ... 60 °C (Standard, applications with UL approval, use in zone 2 potentially explosive area)
  • Designation
    Supply for analog modules (UA)
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section AWG min.
    24
  • Degree of pollution
    2 (IEC 60664-1, EN 60664-1)
  • Transmission speed
    100 Mbps
  • Number of inputs
    4 (for resistance temperature detectors)
  • Sensor types (RTD) that can be used
    Pt, Ni, KTY, Cu sensors
  • Linear resistance measuring range
    0 Ω ... 500 Ω
  • Measured value representation
    16 bits (15 bits + sign bit)
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • Caption
    Dimensional drawing
  • Note on dimensions
    The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Connection method
    Spring-cage connection with direct connector-in method
  • Conductor cross section solid max.
    1.5 mm²
  • Mounting type
    DIN rail
  • Net weight
    144 g
  • Note on weight specifications
    with connectors and bus base module
  • Supply voltage
    24 V DC
  • Input name
    Analog inputs
  • A/D converter resolution
    24 bit
  • Input filter time
    40 ms
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • Width
    35 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Degree of protection
    IP20
  • Conductor cross section flexible max.
    1.5 mm²
  • Stripping length
    8 mm
  • Mounting position
    any (no temperature derating)
  • Number of interfaces
    2
  • Supply voltage range
    19.2 V DC ... 30 V DC (including all tolerances, including ripple)
  • Description of the input
    Inputs for resistive temperature sensors
  • Nominal value of the current sources
    1 mA (Pt 100, Ni 100, RLin 500 Ω; pulse current, the specification is valid during the sampling phase)
  • Type of protection
    Short-circuit protection, overload protection of the inputs
  • Test section
    5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
  • Interference emission
    Noise emission test according to EN 61000-6-3 Class B
  • IECEx
    Ex ec IIC T4 Gc
  • ECLASS 10.0.1
    27242601
  • ETIM 6.0
    EC001596
  • Overvoltage category
    II (IEC 60664-1, EN 60664-1)
  • ECLASS 9.0
    27242601
  • REACh SVHC
    Lead 7439-92-1
  • Mechanical tests
    Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts