1028069 Phoenix Contact Terminal Blocks
Part#:1028069
Manufacturer:Phoenix Contact
Category:Terminal Blocks
Product Lifecycle:Active
Get a quick Quote!
Distribution block, Basic terminal block, nom. voltage: 450 V, nominal current: 24 A, connection method: Push-in connection, number of connections: 2, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, width: 5.2 mm, height: 21.7 mm, color: red, mounting type
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1028069 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Result of voltage-drop test Test passed
- Ageing test for screwless modular terminal block temperature cycles 192
- Result of thermal test Test passed
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Nominal cross section 2.5 mm²
- Maximum load current 27 A
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Result of flexion and pull-out test Test passed
- Bending test rotation speed 10 rpm
- Potentials 1
- Color red
- Degree of pollution 3
- Nominal voltage UN 450 V
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Bending test conductor cross section/weight 0.14 mm² / 0.2 kg
- Result of temperature-rise test Test passed
- Setpoint 1 N
- Short-time current 0.48 kA
- ASD level 6.12 (m/s2)2/Hz
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Connection method Push-in connection
- Conductor cross section flexible max. 2.5 mm²
- ECLASS 9.0 27141120
- ETIM 3.0 EC000897
- UNSPSC 13.2 39121410
- Number of connections 2
- Rated surge voltage 6 kV
- Maximum power dissipation for nominal condition 0.77 W
- Open side panel No
- Result of power-frequency withstand voltage test Test passed
- Back of the hand protection guaranteed
- Result of tight fit on support Test passed
- Short circuit stability result Test passed
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Acceleration 30g
- Shock test result Test passed
- ECLASS 4.0 27141121
- ECLASS 6.0 27141100
- ETIM 7.0 EC000897
- UNSPSC 12.01 39121410
- Insulating material PA
- Insulating material group I
- Nominal current IN 24 A
- Result of surge voltage test Test passed
- Bending test turns 135
- Tight fit on carrier NS 35
- Conductor cross section short circuit testing 4 mm²
- Oscillation, broadband noise test result Test passed
- Test duration per axis 5 h
- Number of shocks per direction 3
- Stripping length 8 mm ... 10 mm
- Height 21.7 mm
- Min. AWG conductor cross section, flexible 26
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 4.1 27141121
- UNSPSC 7.0901 39121410
- ETIM 4.0 EC000897
- UNSPSC 19.0 39121410
- ECLASS 5.1 27141120
- UNSPSC 11 39121410
- UNSPSC 21.0 39121410
- Number of levels 1
- Flammability rating according to UL 94 V0
- Overvoltage category III
- Finger protection guaranteed
- Power frequency withstand voltage setpoint 1.89 kV
- ECLASS 11.0 27141120
- Shock duration 18 ms
- Length 28.6 mm
- Conductor cross section solid max. 4 mm²
- Conductor cross section AWG min. 26
- Conductor cross section AWG max. 12
- Max. AWG conductor cross section, flexible 12
- ECLASS 10.0.1 27141120
- ECLASS 5.0 27141120
- ECLASS 7.0 27141120
- ETIM 6.0 EC000897
- UNSPSC 6.01 30211811
- Test spectrum Service life test category 2, bogie-mounted
- Test directions X-, Y- and Z-axis (pos. and neg.)
- UNSPSC 18.0 39121410
- UNSPSC 20.0 39121410
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Static insulating material application in cold -60 °C
- Tensile test result Test passed
- Relative insulation material temperature index (Elec., UL 746 B) 125 °C
- Connection in acc. with standard IEC 60998-2-2
- Conductor cross section flexible min. 0.14 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm²
- Note When aligning several blocks, the foot elements should be placed in a way that maximum 5 blocks are free-hanging in between. Flange elements should be placed after every 9 blocks.
- Result of aging test Test passed
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.34 mm²
- Internal cylindrical gage A3
- Permissible humidity (storage/transport) 30 % ... 70 %
- Ambient temperature (assembly) -5 °C ... 70 °C
- Shock form Half-sine
- Conductor cross section solid min. 0.34 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 2.5 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Width 5.2 mm
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.34 mm²
- Connection cross sections directly pluggable 0.34 mm² 4 mm² 24 12
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- Ambient temperature (actuation) -5 °C ... 70 °C
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?