1027904 Phoenix Contact Programmable Logic Controllers
Part#:1027904
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline F, Digital output module, Digital outputs: 16, 24 V DC, 500 mA, connection method: 2-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1027904 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- ECLASS 6.0 27242600
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Degree of protection IP20
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible max. 1.5 mm²
- Note on weight specifications with connectors and bus base module
- Number 2
- Supply voltage 24 V DC
- Protection max. 8 A (polarity reversal protection up to 5 A)
- Nominal load, inductive max. 12 VA (1.2 H, 48 Ω, with nominal voltage)
- Output current when switched off max. 300 µA
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Depth 54 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- REACh SVHC Lead 7439-92-1
- Height 129.9 mm
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Designation Supply for digital output modules (UO)
- Connection method Push-in connection
- Mounting type DIN rail
- Conductor cross section AWG min. 24
- Mounting position any (no temperature derating)
- Power consumption max. 240 W (of which 1.3 W constitute internal losses)
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Number of outputs 16
- Nominal load, ohmic max. 12 W (48 Ω, with nominal voltage)
- Behavior with overload Shutdown with automatic restart
- Test section 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 10.0.1 27242604
- ECLASS 9.0 27242604
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- Width 35 mm
- Ambient temperature (operation) -25 °C ... 60 °C
- Behavior with inductive overload Output can be destroyed
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- China RoHS Environmentally Friendly Use Period = 50 years
- ETIM 6.0 EC001599
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section AWG max. 16
- Color traffic grey A RAL 7042
- Degree of pollution 2 (IEC 60664-1, EN 60664-1)
- Current consumption max. 8 A (provide external protection)
- Protective circuit Short-circuit protection, overload protection of the outputs electronic
- Output voltage 24 V DC
- Switching frequency max. 10000 per second (with at least 50 mA load current)
- Reverse voltage resistance to short pulses limited protection up to 0.5 A for 1 s
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- Conductor cross section solid max. 1.5 mm²
- Overvoltage category II (IEC 60664-1, EN 60664-1)
- ETIM 7.0 EC001599
- Transmission speed 100 Mbps
- Net weight 212.8 g
- Stripping length 8 mm
- Load min. 10 kΩ
- Nominal load, lamp max. 12 W (at nominal voltage)
- ECLASS 11.0 27242604
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Output name Digital outputs
- ECLASS 7.0 27242604
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Connection technology 2-conductor
- Nominal output voltage 24 V DC
- Output voltage when switched off max. 1 V
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?