Safety relay for emergency stop, safety doors and light grids up to SILCL 3, Cat. 4, PL e, 1- or 2-channel operation, automatic or manual, monitored start, 2 enabling current paths, 1 signal output, TBUS interface, US = 24 V DC, pluggable screw terminal b
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1009831 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 112.2 mm
- Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
- Designation Air clearances and creepage distances between the power circuits
- Inrush current min. 10 mA
- Input voltage range "1" signal 20.4 V DC ... 26.4 V DC
- Concurrence ∞
- Sq. Total current 72 A2 (observe derating)
- Output fuse 10 A gL/gG
- Typical pickup time at US 200 ms (when controlled via A1)
- Mounting type DIN rail mounting
- Nominal operating mode 100% operating factor
- Assembly instructions See derating curve
- Connection method Screw connection
- Screw thread M3
- Safety Integrity Level (SIL) 3
- Rated surge voltage/insulation Safe isolation, reinforced insulation 6 kV between input circuit and enabling current path (13/14) and enabling current path (23/24)Basic insulation 4 kV between all current paths and housing
- Shock 15g
- ECLASS 10.0.1 27371819
- Ambient temperature (operation) -20 °C ... 55 °C (observe derating)
- Rated control circuit supply voltage US 24 V DC -15 % / +10 % (provide external protection)
- Protective circuit Serial protection against polarity reversal Suppressor diode
- Current consumption typ. 10 mA (Typically with US at Y1)
- Contact material AgSnO2
- Switching capacity min. 100 mW
- Maximum inrush current 500 mA (Δt = 1 ms at Us)
- Typical response time at US 200 ms (automatic start)
- Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- Degree of protection IP20
- Operating voltage display 1 x green LED
- Torque 0.5 Nm ... 0.6 Nm
- Safety Integrity Level Claim Limit (SIL CL) 3
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- ECLASS 9.0 27371819
- Width 22.5 mm
- Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
- Rated control supply current IS typ. 75 mA
- Description of the input non-safety-related
- Max. permissible overall conductor resistance 50 Ω
- Output name Enabling current path
- Switching voltage min. 10 V AC/DC
- Mechanical service life 10x 106 cycles
- Typical release time at US 25 ms (when actuation is via the sensor circuit)
- Min. degree of protection of inst. location IP54
- Housing color yellow
- pluggable Yes
- Category 4 (5 A DC13; 5 A AC15; 8760 switching cycles/year)
- Conformance CE-compliant
- ECLASS 11.0 27371819
- ETIM 6.0 EC001449
- Depth 114.5 mm
- Maximum altitude ≤ 2000 m (Above sea level)
- Input name Start circuit
- Protective circuit/component Suppressor diode
- Output description PNP
- Switching frequency max. 0.5 Hz
- Voltage approx. 23.9 V DC (Us - 0.1 V)
- Restart time < 1 s (Boot time)
- Mounting position vertical or horizontal
- Status display 4 x green LEDs
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Stripping length 7 mm
- Performance level (PL) e
- Rated insulation voltage 250 V
- Degree of pollution 2
- Overvoltage category III
- REACh SVHC Lead 7439-92-1
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (storage/transport) -40 °C ... 70 °C
- Power consumption at US typ. 1.8 W
- Filter time No darkness test pulses / low test pulses permitted. No brightness test pulses / high test pulses permitted.
- Number of inputs 3
- Number of outputs 1
- Contact type 2 enabling current paths
- Limiting continuous current 6 A
- Switching capacity according to IEC 60947-5-1 5 A (24 V (DC13))
- Current max. 100 mA
- Recovery time < 500 ms
- Net weight 169.38 g
- Housing material PBT
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Conductor cross-section AWG 24 ... 12
- Stop category 0
- Standards/regulations DIN EN 50178
- China RoHS Environmentally Friendly Use Period = 50 years
- ETIM 7.0 EC001449
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?