1009222 Phoenix Contact Data & Networking Devices
Part#:1009222
Manufacturer:Phoenix Contact
Category:Data & Networking Devices
Product Lifecycle:Active
Get a quick Quote!
Managed Switch 2000, 6 RJ45 ports 10/100/1000 Mbps, 2 SFP ports 100/1000 Mbps, degree of protection: IP20, PROFINET Conformance-Class B, PROFINET mode preset, PROFINET status LEDs
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Data & Networking Devices that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1009222 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- ECLASS 4.0 27250501
- ECLASS 5.1 19030100
- UNSPSC 19.0 43222612
- Utilization restriction Use in potentially explosive areas is not permitted in China.
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)
- Interface SFP module
- Transmission physics Depending on the SFP module
- Management Web-based management (HTTP/HTTPS)
- IP parameterization DHCP-Client
- MAC address table 8k
- Residual ripple 3.6 VPP (within the permitted voltage range)
- Max. current consumption 1.5 A (US = Min, Tamb = Max, DOI = Max)
- MTTF 491.44 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
- Conductor cross section flexible min. 0.25 mm²
- Conductor cross section flexible max. 1.5 mm²
- Immunity to surge EN 61000-6-2 EN 61000-4-5 (surge) Criterion B
- Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
- Shipbuilding approval Tested in accordance with IEC 60945 and IACS E10
- UL, USA UL 60079-0, Ed.6 / UL 60079-7, Ed.5
- China RoHS Environmentally Friendly Use Period = 50 years
- UNSPSC 6.01 43172015
- UNSPSC 20.0 43222612
- IECEx Ex ec IIC T4 Gc
- ECLASS 11.0 19170401
- Height 130 mm
- Ambient temperature (operation) -40 °C ... 70 °C
- Basic functions Store-and-forward switch, complies with IEEE 802.3
- PROFINET device function PROFINET device
- Cascading depth Network, linear, and star structure: any
- Supply voltage range 12 V DC ... 57 V DC
- Net weight 440 g
- Special properties PROFINET mode preset, PROFINET status LEDs
- Conducted noise emission EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A
- Immunity to ESD EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
- Free from substances that could impair the application of coating Yes
- Noise immunity EN 61000-6-2
- REACh SVHC Lead 7439-92-1
- ECLASS 7.0 19170106
- ETIM 3.0 EC000734
- UNSPSC 12.01 43201410
- Degree of protection IP20
- Degree of pollution 2
- Air pressure (operation) 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating)
- No. of ports 2 (SFP ports)
- Transmission length up to 80 km (Depending on the fiber/SFP module used)
- Filter functions Quality of Service (8 priority classes)
- Time synchronization SNTP (Simple Network Time Protocol)
- Status and diagnostic indicators LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (link/activity and speed), PROFINET status LEDs (BF, SF)
- Type AX Book type
- Connection method Push-in spring connection
- Conductor cross section AWG max. 16
- Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A
- Type of test Free fall in accordance with EN 61131-2
- Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6
- UL, Canada CSA C22.2 NO.60079-0, Ed.3 / CSA C22.2 NO.60079-7:16
- ETIM 4.0 EC000734
- UNSPSC 7.0901 43201404
- Signal LEDs Data receive, link status
- ATEX II 3 G Ex ec IIC T4 Gc
- ECLASS 5.0 19030100
- ECLASS 6.0 19170100
- UNSPSC 11 43172015
- Depth 115 mm
- Permissible humidity (operation) 10 % ... 95 % (non-condensing)
- Transmission speed 100/1000 Mbps (full duplex)
- Configuration memory max. 8 GByte (SD card)
- Additional functions Jumbo frames (Max. 9,600 bytes)
- Signal contact control voltage typ. 24 V DC
- Supply voltage 24 V DC (redundant)
- Port security MAC-based, RADIUS (IEEE 802.1X)
- Mounting type DIN rail
- Note Support by phone or on-site (fee is charged)
- Conductor cross section solid max. 1.5 mm²
- Stripping length 9 mm
- Immunity to EF EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A
- Noise emission EN 61000-6-3
- Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz
- UL, USA/Canada Class I, Div. 2, Groups A, B, C, D T4Class I, Zone 2, IIC T4
- ETIM 7.0 EC000734
- UNSPSC 18.0 43222612
- Redundancy MRP (Media Redundancy Protocol)
- Diagnostic functions RMON History
- PROFINET conformance class Conformance-Class B
- Maximum conductor length (twisted pair) 100 m
- Typical current consumption 280 mA (at US = 24 V DC and 25 °C ambient temperature)
- Current consumption 280 mA
- ECLASS 4.1 27250501
- ECLASS 9.0 19170106
- UNSPSC 13.2 43222612
- UNSPSC 21.0 43222612
- Width 45 mm
- Air pressure (storage/transport) 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating)
- Note on the connection method Auto negotiation and autocrossing
- Housing material Polycarbonate fiber reinforced
- Conductor cross section solid min. 0.25 mm²
- Conductor cross section AWG min. 24
- Immunity to conducted interference EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
- Shock (operation) 30g (EN 60068-2-27)
- Noxious gas test ISA S71.04.2013 G3 Harsh Group A
- ETIM 6.0 EC000734
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- ECLASS 10.0.1 19170401
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?